OPERATING INSTRUCTIONS
en
5
Electrical installation
26
O P E R A T I N G I N S T R U C T I O N S | GTE20
0.6 ... 0.8 Nm
0.4 ... 0.5 Nm
0.8 ... 1.3 Nm
1
Figure 1: Tightening torque
See
table 3
and
table
4.
1
CAUTION
Please provide adequate strain relief externally for the cable if necessary. The back
cover must be completely sealed before operation.
Figure 2: Alignment of the sensor relative to the object direction
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Pin assignment
–
Cable: Wire color
–
Terminal connection: Pin assignment
Terminal connection:
1.
Untighten the M3 screw on the back cover and remove the back cover.
2.
Lead voltage-free supply cable through the 3/8" MPT (Male Pipe Thread) fitting,
spacer, rubber seal (as illustrated below) and the back cover opening in the right
position horizontally or vertically.
3.
Tighten the 3/8" MPT (Male Pipe Thread) according to
< 0.4 Nm
table 3
and
table
4.
8026845.1GXN/2022-11-05 | SICK
Subject to change without notice