OPERATING INSTRUCTIONS
en
6.3
Setting
6.4
Additional functions
32
O P E R A T I N G I N S T R U C T I O N S | GTE20
Operating reserve
100
3
10
2
1
1
0.5
1
1.5
2
0
(1.64)
(3.28)
(4.92)
(6.56)
Figure 6: GTE20, infrared light
1
Black object, 6 % remission factor
2
Gray object, 18 % remission factor
3
White object, 90 % remission factor
Sensing range setting
The sensitivity (sensing range) is adjusted with the potentiometer (type: 270°). Clock‐
wise rotation: sensitivity (sensing range) increased; counterclockwise rotation: sensitiv‐
ity (sensing range) reduced. It is recommended to place the object within the sensing
range, e.g. see
table
10. Once the sensitivity is set, remove the object from the beam
path. The digital output changes.
Table 10: Sensing range setting
The sensor is adjusted and ready for operation.
Time functions
Time function setting
Time delay selector switch can be set on the device according to
2.5
3
3.5
4
(8.20)
(9.84)
(11.48)
(13.12)
Distance in m (feet)
see table
2.
8026845.1GXN/2022-11-05 | SICK
Subject to change without notice