OPERATING INSTRUCTIONS
6
Commissioning
6.1
Alignment
en
30
O P E R A T I N G I N S T R U C T I O N S | GTE20
RC1
BN
BU
WH
BK
GY
Visible red light: Align the sensor with the object. Select the position so that the red
emitted light beam hits the center of the object. You must ensure that the optical
opening (front screen) of the sensor is completely clear [see
Infrared light: Align the sensor with the object. Select the position so that the infrared
light (not visible) hits the center of the object. The correct alignment can only be
detected via the LED indicators. See
optical opening (front screen) of the sensor is completely clear.
Figure 3: Alignment 1
Relay
BN
L1
L1
BU
N
N
WH
BK
GY
figure 3
and
table
I
=
3 A @ 250 V AC
max
4 A @ 24 V DC
0.22 A @ 250 V DC
UL:
4 A @ 250 V AC, general use
4 A @ 250 V AC, resistive (NO)
3 A @ 250 V AC, resistive (NC)
4 A @ 24 V DC, NO, general use
3 A @ 24 V DC, NC, general use
R300/B300 (NO contacts only)