4.
Connect and secure each of the wires to the terminal block with a torque of 0.4 to
0.5 Nm
(table
8).
5.
Put the back cover back. Ensure the back cover is free of obstruction and securely
tightened.
6.
Tighten the M3 screw with a torque of 0.6 to 0.8 Nm.
7.
Seal the other opening with the plastic nut (with rubber) provided in the package.
A
ØB
C
Table 3: Connection values, 1
L (A)
1
2
3
4
5
Table 4: Connection values, 2
C
1 (PVC)
1 (PUR)
2 (PVC/PUR)
3 (PVC/PUR)
Only apply voltage and switch on the voltage supply once all electrical connections have
been established.
NOTICE
Only switch on the voltage supply once all electrical connections have been established
and the terminal chamber has been properly secured.
Explanation of the connection terminology used in the following tables:
1
46 mm
41 mm
31 mm
26 mm
21 mm
Ø B [mm]
5.8 ... 6.7
5.8 ... 6.7
6.8 ... 7.7
7.8 ... 8.2
O P E R A T I N G I N S T R U C T I O N S | GTE20
OPERATING INSTRUCTIONS
1
2
2
57 mm
52 mm
42 mm
37 mm
32 mm
Torque [Nm]
1.3 ... 1.5
1.5 ... 1.7
1.7 ... 2.0
1.7 ... 2.0