Specifications
Display: 4000-count LCD
Polarity: Automatic
Numeric Display Sampling Rate: 3 per second
Temperature Coefficient: Nominal 0.2 x (specified accuracy) per °C
below 18 °C or above 28 °C
Automatic Power Off: After 15 minutes of inactivity.
To disable this feature, press any button while turning the meter on.
Operating Conditions:
Temperature: 0 °C to 40 °C (32 °F to 104 °F)
Relative Humidity (non-condensing): 75% maximum for temperatures up to 31 °C (88 °F),
decreasing linearly to 50% maximum at 40 °C (104 °F)
Altitude: 2000 m (6500') maximum
Indoor use only
Pollution Degree: 2
Storage Conditions:
Temperature: –10 °C to 50 °C (14 °F to 122 °F)
Relative Humidity (non-condensing): 0% to 85%
Remove battery.
Battery: One 9 V battery (6F22)
Overload Protections:
Input Terminal: 400 mA/600 V fast-acting fuse, minimum interrupting rating 20 kA,
13/32" x 1-1/2" or 13/32" x 1-3/8"
10A Terminal: 10 A/600 V fast-acting fuse, minimum interrupting rating 20 kA, 13/32" x 1-1/2"
Overvoltage Category: Category III 600 V
E.M.C: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2,
EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)