Possible voltage variants
Voltage variant 1
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Circuit breaker trip characteristic
Minimum cross-section for connection cable
Voltage variant 2
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Circuit breaker trip characteristic
Minimum cross-section for connection cable
Voltage variant 3
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Circuit breaker trip characteristic
Minimum cross-section for connection cable
Air intake
Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of an appliance).
There must be sufficient air intake to the installation site to match the air outlet volume.
Vented system
Maximum nominal volume flow rate
Maximum permitted pressure loss
Connector on machine side (external diameter)
Connection pipe provided on site (internal diameter)
Maximum exhaust air temperature
As relative humidity inside the exhaust ducting can be as high as 100 %, suitable measures must be taken to prevent a backflow of
condensate into the appliance.
en - Technical data
Standard connection
3N AC 400 V
Standard connection
1N AC 230 V
Standard connection
3 AC 230 V
50/60 Hz
8,2 kW
3 × 16 A
Model B
1,5 mm²
50/60 Hz
5,5 kW
1 × 25 A
Model B
2,5 mm²
50/60 Hz
8,2 kW
3 × 25 A
Model B
2.5 mm²
237 cm²
320 m³/h
220 Pa
100 mm
100 mm
80 °C
37