The equipments are prepared to work with an electric generator. However, these generators must meet certain requi-
rements. It is recommended to use three-phase generators with a constant power of at least 25KVA. If the generator
does not have enough power or the output voltage is outside the machine's operating limits, this could affect the sta-
bility of the welding arc and, therefore, the quality of the weld joint. In the worst case, it may even cause damage to
the machine.
Do not use more than one welding machine with the same generator. Sudden changes in charge level may affect the
stability of the welding arc.
6 - Start the machine by turning the switch on the back of the power unit. During the start up sequence, the equip-
ment performs an internal test. If a fault is detected, the associated code will appear on the front panel display.
Always start or stop the machine using the rear switch, NOT by plugging or unplugging it from the mains

FRONT PANEL LAYOUT

1- Selector of welding type
2- MMA welding mode
3- TIG welding mode
4- MIG - MAG welding mode
5- 2T mode
6- 4T mode
7- Amps visualization
8- Speed in m/min.
9- Welding thickness
10- Arc height
11-Time (0,1s)
SOLTER
SOLDADURA S.L.
ATTENTION
Do not stop the machine while welding.
12- Volts visualization
13- Percentage (%)
14- Arc dynamics (inductance)
15- Values display
16- Parameters display
17- Menu selector
18- Remote control
19- Main selector
20- Synergic or manual selector
21- Manual mode
22- Synergic mode
AEROPROCESS
23- Power output activated
24- Cooler activated
25- Remote control activated
26- Common problems
27- Wire diameter selector
28- Standard material selector
29- OP: Other materials
8