<<CHART A>>
Camera
Lens Type
F5
D, G Type
F100
F90X/N90ser.
AF lens other than
F80/N80ser.
D, G type
F70D/N70
Without Built in CPU
F75/N75
F4 Series
With Built-in CPU
F-801S/N8008S
F-801/N8008
F65/N65
Without
Pronea 600i
Built-in CPU
With Built-in CPU
F601/N6006
F-601M
Without
Built-in CPU
F60D/N60
With Built-in CPU
F50D/N50
Without
F-401X/4004S
Built-in CPU
Built-in CPU lens
,Ai-S, Ai, Series E,
F501/N2020
AF F3 Lens
F301/N2000
Except above
lenses
With Built-in CPU
F401S/N4004S
F401/N4004
Without Built-in CPU
FA, FE2
With Built-in CPU;
Without Built-in CPU
FG, F3, FM3
Confirm Distance:
1 : Flash's LCD panel will show the F-number and working distance of flash automatically.
2 : Set the F-number on the flash to be the same as camera, and check the available working distance range on the
LCD panel. To set the F-number on the Flash, push the SEL button until the F-number blinks, and use + or – button
to set the F-number. Then press the SEL button again. The F-number will stop blinking.
◆ When using Digital SLR cameras, functions will vary depending on the lens type and combinations of exposure
modes, same as F5 and F100 group (in chart A), however, they will use D-TTL (i-TTL).
LIMITS OF CONTINUOUS SHOOTING
To prevent overheating of the flash's circuitry, do not use your Flash unit for at least 10minutes after
continiously using the flash as shown in the table below.
Mode
TTL, M(1/1,1/2)
M(1/4, 1/8)
M(1/16-1/32)
Multi
MANUAL FLASH OPERATION
Manual flash is provided for shooting subjects when the correct exposure
is difficult to obtain in the TTL mode. In the manual flash mode, you can
set the flash power level from 1/1 to 1/64 power in 1/3 stop increments.
1. Set the camera's exposure mode (A, M modes).
2. Press the MODE button on the flash unit to select M.
3. Press the SEL button to make the guide number value blink.
4. Press + or – button to set the desired flash power output.
5. To stop the manual flash output display blinking, Press the SEL button again.
6. When the Ready Light of the flash is illuminated, the unit is ready for use.
17
Exp. Mode Metering
All Modes
All Modes
All Modes
All Modes
A/M
Center-weighted,
Modes
Spot Metering
Matrix Pattern
All Modes
Center-weighted,
Spot Metering
A/M
Center-weighted,
Modes
Spot Metering
Matrix Pattern
All Modes
Center-weighted,
Spot Metering
A/M
Center-weighted,
Modes
Spot Metering
P/S
A/M
M
P
A/M
A/M
P/S
A/M
M
A/M
TTL System
Note
3-D Multi-Sensor
BL
Can switch to TTL Mode. With
F5, F100, F80, series Cameras
Multi-Sensor BL
spot metering system is always
TTL.
Center Weighted /
Spot Fill-Flash
TTL BL
Can switch to TTL Mode. TTL BL
Center Weighted /
can work with only F4 series, AF
F3, Ai-S, Ai, Series E lens. Spot
Spot Fill-Flash
metering system of F4 is always
Center
TTL. Pronea 600i will be TTL,
Weighted/Spot
when exposure mode is "M".
Fill-Flash
Center Weighted BL cannot work.
TTL BL
Center Weighted /
Spot Metering cannot use with
Spot Fill-Flash
F-601M
Center Weighted /
Spot Fill-Flash
If exposure mode is "M", it will be
TTL BL
Center Weighted/Spot Fill-Flash
Center Weighted /
Spot Fill-Flash
TTL Programmed
TTL
TTL
TTL Programmed
TTL
TTL
TTL
Number of Flash Exposures
15 Continuous Flash Shots
20 Continuous Flash Shots
40 Continuous Flash Shots
10 Cycle
Conf
Dist
1
2
1
2
2
2
2
2
2
2
2