MICROPHONE SETTING MENU
The IG2T allows the input of a microphone with XLR connector. When
using this source, it may be useful to apply a filtering to the signal to
cut any unwanted frequencies (by a high-pass filter with adjustable cut
frequency). Or it may be necessary to intervene (by a notch or band-stop
filter with selectable band centre) to prevent any feedback (or Larsen
effect). To perform one of these settings, or both of them, after accessing
the MICROPHONE SETTING menu:
1. Select and confirm HP filter (high-pass filter)
2. Select and confirm the value of the high-pass filter cut frequency, with
a range of 50 Hz – 200 Hz and a resolution of 10 Hz (select the "None"
value if you wish to disable the filter)
3. Select and confirm "Antifeedback" (anti-feedback or anti-Larsen effect
filter)
4. Select and confirm the value of the band centre frequency, with a
range of 260 Hz – 15000 Hz and a resolution of 10 Hz (select the
"None" value if you wish to disable the filter)
5. Return to the initial screen by selecting the "HOME" symbol
INGENIA IG2T
Wide indoor environment setting
Microphone Setting Menu
Cod. 420120238 REV. 1.1