– Contaminations containing protein, i.e.
in the food processing industry
max. 60 °C
– Vehicle cleaning, machine cleaning
60-90 °C
– De-preserve, contaminations contain-
ing strong fat contents
100-110 °C
– De-frosting of surcharge substances,
partially facade cleaning
up to 140 °C
Operating with hot water
DANGER
Scalding danger!
Set temperature regulator to desired
temperature.
Operating with steam
DANGER
Scalding danger! The work pressure must
not exceed 3.2 MPa (32 bar) when operat-
ing with temperatures above 98 °C.
Therefore the following measures must
definitely be performed:
Replace high pressure nozzle (stain-
less steel) with steam nozzle (brass,
order see specification).
Open up the pressure/ quantity regula-
tor on the hand spray gun completely,
direction + until stop.
Set the working pressure/quantity regu-
lation at the pump unit to the minimum
quantity.
Set temperature regulator to min.
100 °C.
Interrupting operation
Secure the trigger gun. To do so, push
the safety catch towards the front.
After operation with detergent
Set dosing value for detergent to "0".
Set the appliance switch to "1" (opera-
tion with cold water).
Open the hand spray gun and rinse the
appliance for at least 1 minute.
30
Turn off the appliance
DANGER
Danger of scalding from hot water! After the
operation with hot water or steam, the de-
vice must be operated with opened gun
with cold water for at least two minutes.
Shut off water supply.
Open the hand spray gun.
Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
Close the hand spray gun.
Set the appliance switch to "0/OFF".
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until device is
pressure less.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Storing the Appliance
Lock in the steel pipe into the holder of
the appliance hood.
Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Note: Do not twist high pressure hose and
electrical conduit.
Frost protection
ATTENTION
Risk of damage! Frost will destroy the appli-
ance if the water has not been completely
drained.
Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
ATTENTION
Threat of damage by penetrating cold air
through the chimney.
Disconnect device from chimney when
outside temperature drops below 0 °C.
If it is not possible to store frost free, shut
down device.
– 8
EN