Rotation direction symbol
Figure 8
Exchange the poles at the appliance
plug.
Engine symbol
– Engine overload/overheat
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
Electrical symbol
– Contactor error
Set the appliance switch to "0/OFF".
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
– Fault in the voltage supply.
Check main connections and mains
fuse.
– Excessive power consumption.
Check main connections and mains
fuse.
Inform Customer Service.
Water shortage symbol
– Water shortage
Check water supply, check connections.
Burner error symbol
– The exhaust temperature limiter has
been triggered.
Set the appliance switch to "0/OFF".
Allow device to cool down.
Turn on the appliance.
– Error occurs repeatedly.
Inform Customer Service.
– Leak in the high pressure system
Check high pressure system and con-
nections for tightness.
Inform Customer Service.
Flame sensor symbol
– The flame sensor turned the burner off.
Inform Customer Service.
System care detection symbol
– System care detection defective
Inform Customer Service.
System care symbol
Note: Burner can operate 5 more hours.
– System care tank is empty, due to tech-
nical reasons a remainder stays in the
tank.
Refill system care.
– 11
EN
Error symbol
33