12 REVIEWING BATCH DATA (continued)
If limits were not set and enabled, the readings are displayed as white
vertical bars. If limits were set and enabled, readings are displayed as
white bars if within set limits or red; if outside set limits.
If there are more readings in the batch
than can be displayed on a single
screen, multiple readings will be
combined into one bar. Should a single
reading within the 'combined bar' be
outside set limits, the whole bar will be
red.
Pressing the 'Zoom+' softkey, allows
each individual reading to be displayed,
thereby showing the individual readings
outside the set limits.
When zoomed in, the graph will always
display the first 25 readings. Pressing
the softkey will display the last 25
readings in the batch.
Subsequent presses of the softkey will scroll backwards, pressing
the softkey will scroll forwards through the readings, 25 readings at
a time.
Pressing the 'Zoom-' softkey returns to the original overview graph of
all readings in the batch.
Pressing the 'Back' softkey returns the gauge to the Batch/Review
Batch menu.