Descargar Imprimir esta página

Stanley SXPW2823 Manual De Instrucciones página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

NOZZLE CLEANING (FIG. 14)
If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure
may develop. If the nozzle becomes partially clogged or restricted, the pump pressure
will pulsate. Clean the nozzle immediately using the nozzle kit supplied and the
following instructions:
1.
Shut off the pressure washer and turn off the water supply.
2.
Pull trigger on gun handle to relieve any water pressure.
3.
Disconnect the spray wand from the gun.
4.
Remove the high pressure nozzle (K) from the spray wand.
Remove any obstructions with the nozzle cleaning tool
provided and backflush with clean water.
5.
Direct water supply (N) into nozzle to backflush loosened
particles for 30 seconds.
6.
Reassemble the nozzle to the wand.
7.
Reconnect spray wand to gun and turn on water supply.
8.
Start pressure washer and place spray wand into high
pressure setting to test.
CLEAN THE WATER INLET FILTER (FIG. 10)
This screen filter should be checked periodically and cleaned if necessary.
1.
Remove filter by grasping end and removing it from water inlet of pump.
2.
Clean filter by flushing it with water on both sides.
Re-insert filter into water inlet of pump. NOTE: Cone side faces out.
3.
NOTE: Do not operate the pressure washer without filter properly installed.
ENGINE
Consult the Engine Owner's Manual for manufacturer's recommendations
for storage.
TO PREVENT FUEL-RELATED PROBLEMS
1.
Add Ethanol Shield
adding a gasoline stabilizer, fill the fuel tank with fresh gasoline. If only partially
filled, air in the tank will promote fuel deterioration during storage. If you keep a
container of gasoline for refueling, be sure that it contains only fresh gasoline.
2.
After adding a gasoline stabilizer, run the engine outdoors for 10 minutes to be sure
that treated gasoline has replaced the untreated gasoline in the carburetor.
3.
Turn the fuel valve to the OFF position.
4.
Continue to run the engine until it stops from the lack of fuel in the carburetor fuel
bowl. Running time should be less than 3 minutes.
PUMP
The manufacturer recommends using SIMPSON
or equivalent when storing the unit for more than 30 days and/or when freezing tem-
peratures are expected. SIMPSON
tally friendly.
NOTE: Using pump guard helps provide proper lubrication to the internal seals of the
pump regardless of temperature or environment.
STORAGE
fuel stabilizer following the manufacturer's instructions. When
TM
/ POWERWASHER
®
19 - ENG
14
N
/ POWERWASHER
®
®
Pump Guard is environmen-
®
K
K
Pump Guard

Publicidad

loading

Este manual también es adecuado para:

Sxpw3124