en
Do not direct the power tool against yourself, other per-
sons or animals. Danger of injury from sharp or hot
application tools.
Beware of any concealed electric cables, gas or water
conduits. Check the working area before commencing
work, e. g. with a metal detector.
Use a stationary extraction system, blow out ventilation
slots frequently and connect a residual current device
(RCD) on the line side. When working metal under
extreme operating conditions, it is possible for conduc-
tive dust to settle in the interior of the power tool. The
total insulation of the power tool can be impaired.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection
against an electric shock will be ineffective. Adhesive
labels are recommended.
Always work with the auxiliary handle. The auxiliary
handle ensures reliable guiding of the power tool.
After working gypsum-containing materials: Blow out
the ventilation openings of the power tool and the
switch element with dry and oil-free compressed air.
Otherwise, gypsum-containing dust can settle in the
power tool housing and switch element, which can
harden in connection with humidity. This can impair the
switching mechanism.
Before putting into operation, check the mains connec-
tion and the mains plug for damage.
Recommendation: The tool should always be supplied
with power via a residual current device (RCD) with a
rated current of 30 mA or less.
Hand/arm vibrations
The vibration emission level given in this information
sheet has been measured in accordance with a stand-
ardised test given in EN 60745 and may be used to
compare one tool with another. It may be used for a
preliminary assessment of exposure.
The declared vibration emission level represents the
main applications of the tool. However, if the tool is
used for different applications, with different accesso-
ries or poorly maintained, the vibration emission may
differ. This may significantly increase the exposure level
over the total working period.
An estimation of the level of exposure to vibration
should also take into account the times when the tool
is switched off or when it is running but not actually
doing the job. This may significantly reduce the expo-
sure level over the total working period.
Identify additional safety measures to protect the oper-
ator from the effects of vibration such as: maintain the
tool and the accessories, keep the hands warm, organi-
sation of work patterns.
Handling hazardous dusts
For work procedures with this power tool where
material is removed, dusts develop that can be hazard-
ous to one's health.
Contact with or inhaling some dust types, e. g. asbestos
and asbestos-containing materials, lead-containing coat-
ings, metal, some wood types, minerals, silicate parti-
cles from materials containing stone, paint solvents,
wood preservatives, antifouling paints for vessels, can
trigger allergic reactions to the operator or bystanders
and/or lead to respiratory infections, cancer, birth
defects or other reproductive harm. The risk from
inhaling dusts depends on the exposition. Use dust
extraction matched appropriately for the developing
dust, as well as personal protective equipment and pro-
vide for good ventilation of the workplace. Leave the
processing of asbestos-containing materials to special-
ists.
Wood and light-metal dust, hot mixtures of grinding
dust and chemical materials can self-ignite under unfa-
vourable conditions or cause an explosion. Avoid
sparking in the direction of the dust collector as well as
overheating of the power tool and the materials being
sanded, empty the dust collector/container in time,
observe the material manufacturer's working instruc-
tions, as well as the relevant regulations in your country
for the materials being worked.
Operating Instructions.
Press the locking button only when the motor is
stopped (see page 5). Otherwise the power tool
may be damaged.
Features
The soft start is used to reduce torque reaction forces
when switching on and running up the power tool to
the no-load speed.
The restarting protection prevents the power tool from
automatically restarting if the power supply is inter-
rupted during operation. In this case, switch off the
power tool, check the power supply and then switch
the power tool on again.
Repair and customer service.
Please observe that power tools may only be
repaired, maintained and inspected by qualified
electricians, as improper maintenance can result in con-
siderable hazards for the user.
When working metal under extreme oper-
ating conditions, it is possible for conductive
dust to settle in the interior of the power
tool. The total insulation of the power tool can be
impaired. Blow out the interior of the power tool via
the ventilation slots frequently with dry and oil-free
compressed air, and connect a residual current device
(RCD) on the line side.
When working gypsum-containing materials, dust can
settle within the power tool and switch element, which
can harden in connection with humidity. This can
impair the switching mechanism. Blow out the interior
of the power tool via the ventilation slots and the
switch element frequently with dry and oil-free com-
pressed air.
Products that have come into contact with asbestos
may not be sent in for repair. Dispose of products con-
taminated with asbestos according to the applicable
country-specific regulations for such disposal.
For FEIN power tools and accessories in need of repair,
please contact your FEIN after-sales service. The
address can be found on the Internet under
www.fein.com.