Descargar Imprimir esta página

Bosch GSR 18V-150 C Professional Manual Original página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
20 | English
Press the button for the battery charge indicator  or
show the state of charge. This is also possible when the bat-
tery is removed.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
Note: The state of charge of the battery is also displayed on
the user interface (14) (see "Status Indications", page 22).
Battery model GBA 18V...
LEDs
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
Battery model ProCORE18V...
LEDs
5× continuous green light
4× continuous green light
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
Auxiliary handle
Do not operate your power tool without the auxiliary
u
handle (4).
This power tool must only be used with the auxiliary
handle with the order number 1 602 025 07Y.
Before carrying out any work, make sure that the aux-
u
iliary handle is tightened. Loss of control can cause per-
sonal injury. Ensure that the auxiliary handle is tightened
with a torque suited to the fastening method; fasten this
to the power tool so that any movement of the auxiliary
handle around or along the drilling axis is avoided.
Fitting the auxiliary handle
To open the auxiliary handle, turn the lower gripping end of
the auxiliary handle (4) in an anticlockwise direction.
Pull back the intermediate piece of the auxiliary handle and
hold it in this position.
Slide the auxiliary handle over the drill chuck to mount the
auxiliary handle on the power tool.
Then let go of the intermediate piece .
Afterwards, turn the lower gripping end of the auxiliary
handle (4) clockwise to retighten it.
1 609 92A 6Y0 | (14.09.2021)
to
Swivelling the auxiliary handle
You can swivel the auxiliary handle (4) to any angle for a safe
work posture that minimises fatigue.
Turn the lower gripping end of the auxiliary handle (4) anti-
clockwise and swivel the auxiliary handle (4) into the re-
quired position. Afterwards, turn the lower gripping end of
the auxiliary handle (4) clockwise to retighten it.
Setting the drilling depth
You can use the depth stop (3) to set the required drilling
depth X.
Loosen the wing bolt for adjusting the depth stop (5) and in-
sert the depth stop into the auxiliary handle (4).
Capacity
Pull the depth stop (3) far enough out that the distance
between the drill bit tip and the edge of the depth stop (3)
60−100 %
corresponds to the required drilling depth X.
30−60 %
Retighten the wing bolt for adjusting the depth stop (5).
5−30 %
0−5 %
Changing the tool (see figure A)
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
The drill spindle is locked when the on/off switch (17) is not
Capacity
pressed. This makes it possible to change the application
80−100 %
tool in the drill chuck quickly, conveniently and easily.
60−80 %
Open the keyless chuck (2) by turning it in the direction of
40−60 %
rotation ➊ until the tool can be inserted. Insert the tool.
Firmly tighten the keyless chuck (2) by turning it by hand in
20−40 %
the direction of rotation ➋. This will automatically lock the
5−20 %
drill chuck.
0−5 %
Dust/Chip Extraction
Dust from materials such as lead-containing coatings, some
wood types, minerals and metal can be harmful to one's
health. Touching or breathing-in the dust can cause allergic
reactions and/or lead to respiratory infections of the user or
bystanders.
Certain dust, such as oak or beech dust, is considered carci-
nogenic, especially in connection with wood-treatment ad-
ditives (chromate, wood preservative). Materials containing
asbestos may only be worked by specialists.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filter-class respirator.
Observe the relevant regulations in your country for the ma-
terials to be worked.
Avoid dust accumulation at the workplace. Dust can
u
easily ignite.
Bosch Power Tools