9.
Connect the water supply valve (see Ill.10).
Tighten this connection, finger tight.
10. Flush the water supply line for a few seconds
to remove any debris that may enter the new
fill valve. (For new home constructions and/or
additions, flush the water supply line for more
than a minute to help remove any residual PVC
adhesives, solder flux, and/or pipe sealants that
were used for the new plumbing.)
CA UTION: Avoid using a wrench to tighten the
connection as you may damage the plastic threads
and/or cause the fill valve to rotate inside the tank.
NO TE: The water supply pressure
should be 20 to 80 psi static.
11. No fill valve adjustments are needed. The water
will automatically stop at proper level.
12. Install the toilet tank lid onto the toilet tank top
(see Ill. 10).
13. The toilet seat is installed with the top-mount bolt set
(see Ill. 11). Insert the rubber bushing-nut into the seat
mounting holes. Place the seat on the bowl and rotate
the hinge unit into place while holding the seat down
on the bowl. Tighten the bolt from the top with the
screwdriver.
NO TE: Tighten the seat bolt until the hinge is secure. The
seat and lid will have slight side to side movement,
which is normal. This freedom of movement allows the
seat to SoftClose

FILL VALVE REPLACEMENT INSTRUCTIONS

1.
Shut off the water supply to the toilet. Have paper towels ready in case of spill.
2.
Flush toilet and remove remaining water from tank with a sponge.
3.
Remove the water supply hose from water supply valve on wall/floor.
4.
Unscrew both nuts from bolts under tank. Carefully remove tank from toilet's bowl.
5.
Remove refill tube from fill valve. Remove old fill valve from tank.
6.
Thread mounting nut onto fill valve shank and tighten the nut.
NO TE: Do not over-tighten. Be sure to install fill valve in a position that does not
interfere with the trip lever operation.
7.
Pick up the tank and carefully guide the brass bolts and supply hose to align the
tank with the bowl. Attach and tighten a metal washer and wing nut to each bolt.
8.
Connect water supply hose to supply valve on wall or floor.
NO TE: Do not overtighten. These are plastic parts. Never use pipe dope on any
water supply connection.
Installation Procedure (continued)
without binding.
®
Installation Procedure
Ill. 9
3 Gap
6
YES
3
1 & 2
3
NO
NO
1 & 2
Ill. 10
Ill. 11
Seat Bolt
Rubber
Brushing Net
1 & 2
Gap