Standard (constant current)
2 mm
D
TRIGGER FUNCTIONS
2T MODE
t
t
t
Main button
T1
Main button
T1
Main button
T1
4T MODE
t
t
t
Main button
T1
T2
Main button
T1
T2
Main button
T1
T2
4T MODE log
t
t
t
Main button
T1
T2
Main button
T1
T2
Main button
T1
T2
For double button or double trigger torches, the «high» trigger retains the same functionality as the single trigger or lamella torch. The «low» trigger
is inactive.
ELECTRODE WELDING (MMA/SMAW)
CONNECTION AND ADVICE
• Connect the cables, electrode holder and earth clamp to the connectors.
• Observe the welding polarities and intensities indicated on the electrode boxes.
• Remove the electrode from the electrode holder when the machine is not in use.
• The machine has 3 features exclusive to Inverters:
- The Hot Start creates an overcurrent at the beginning of the weld.
- The Arc Force creates an overcurrent which prevents the electrode from sticking to the weld pool.
- The Anti-Sticking makes it easier to unstick the electrode from the metal.
CHOICE OF COATED ELECTRODES
• Rutile electrode: very easy to use in all positions.
• Basic electrode: usable in all positions, it is suitable for structural work thanks to increased mechanical properties.
• Cellulosic electrode: very dynamic arc with a high melting rate and usable in all positions making it especially suitable for pipe work.
PULSEMIG 320 C
5 mm
D
D
t
t
t
T2
T2
T2
t
t
t
T4
T3
T4
T3
T4
T3
<0.5s
<0.5s
>0.5s
<0.5s
<0.5s
>0.5s
<0.5s
<0.5s
>0.5s
t
t
t
T4
T3
T4
T3
T4
T3
10 mm
5 mm
D
T1 - The main button is pressed, the welding cycle starts (PreGas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped
(DownSlope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the secondary
button works like the main button.
T1 - The main button is pressed, the cycle starts at PreGas and
stops in the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope
and in welding.
T3 - The main button is pressed, the cycle switches to DownSlope
and stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
Nb : for torches, double button and double button with potentiome-
ter
=> command « up/welding current » and active potentiometer,
command «low » inactive.
T1 - The main button is pressed, the cycle starts at PreGas and
stops in the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope
and in welding.
LOG : this mode is used during welding :
- A brief press of the main button (<0.5s), the current switches
from I welding current to I cold and vice versa.
- the secondary button is kept pressed, the welding current swit-
ches from I welding current to I cold
- the secondary button is kept released, the welding current swit-
ched from I cold to I welding current.
T3 – A long press on the main button (>0.5s), the cycle switches to
DownSlope and stops in the I_Stop phase.
T4 - The main button is released, the cycle finishes with PostGas.
E-TIG (constant power)