ims PRO PULSEMIG 320 C Manual De Instrucciones página 45

Publicidad

Idiomas disponibles

Idiomas disponibles

Degression
End current
Stop duration
Post-gas
Access to some welding parameters depends on the selected display mode: Settings/User Level: Easy, Expert, Advanced.
• TIG DC Pulse
This pulsed current welding mode is a combination of high current pulses (I, welding pulse) and low current pulses (I_Cold, part cooling pulse). This
pulse mode is used to prevent the machine from overheating when assembling pieces together.
Example :
The welding current I is set to 100A and % (I_Cold) = 50%, i.e. a cold current = 50% x 100A = 50A.
F(Hz) is set to 10Hz, the signal period will be 1/10Hz = 100ms -> every 100ms, one pulse at 100A then another at 50A will follow one another.
Settings
Designation
Pre-gas
Starting current
Starting time
Rising current
Welding current
Wave shape
Cold current/Back-
ground current
Cold weather
Pulse frequency
Degression
End current
Stop duration
Post-gas
Access to some welding parameters depends on the selected display mode: Settings/User Level: Easy, Expert, Advanced.
ADJUSTMENT TIPS : The choice of frequency
• If welding using filler wire, then synchronise F(Hz) with the filling gesture,
• If thickness is low (< 0.8 mm) and not using filler wire, F(Hz) > 10Hz
• Welding in position, then F(Hz) < 100Hz
PULSEMIG 320 C
0 - 60 secs.
Down slope current.
10 - 200%
This current treshold when stopped is a phase after the current downslope.
0 - 10 secs.
Duration for which gas is released after the arc has stopped. It protects the weld pool
0 - 60 secs.
and the electrode against oxidisation when the metal is cooling down.
Adjustable
settings
0 - 60 secs.
Torch purge time and to protect the area with gas before ignition
10 - 200 %
This current treshold at the start is a phase before the current upslope.
0 - 10 secs.
0 - 60 secs.
Up slope current.
10 - Imax
Welding current.
Waveform of the pulsed part.
20 - 80%
Second welding current known as "cold" welding current
20 - 80%
Time balance of the pulse hot current (I)
0.1 - 2500 Hz
Pulse frequency
0 - 60 secs.
Down slope current.
10 - 200 %
This current treshold when stopped is a phase after the current downslope.
0 - 10 secs.
Duration for which gas is released after the arc has stopped. It protects the weld pool
0 - 60 secs.
and the electrode against oxidisation when the metal is cooling down.
Description & advice
EN
45