SPECIFICATIONS
Measuring ranges
Scaling factor
Output sensitivity
Accuracy (45-65Hz)
Noise
Output Connector
Power Supply
Battery Life (typ.)
Connector
Output load
Frequency range
Phase angle error
Position sensitivity
External field
Temperature coeff.
Low battery
Overload
_______________________________________________________________
60A
40
25mV/A
±1% of rdg. ±0,1A
8 mVrms
Battery
external
≥100 kΩ for specified accuracy
10 Hz to 20 kHz (-10% attenuation)
<±1° (45-65Hz)
±2% of reading
±0.2% of range with cable >200mm
(8") from the probe
±0.1% / °K
Indicated by an orange LED
Indicated by a red LED
METRAFLEX 6001XBL
METRAFLEX 6003XBL
600A
400
2,5mV/A
2 mVrms
4 pin Hypertronics plug
2x AA MN1500 LR6 Alkaline
2000 hrs (M'FLEX 6001XBL)
1000 hrs (M'FLEX 6003XBL)
2...3VDC/max. 100mA
Barrel plug socket 5,5/2,1mm
minus at center pin
6000A
4000
0,25mV/A
±1% of rdg. ±1A
7

Publicidad

loading

Este manual también es adecuado para:

Metraflex 6003xbl