Commissioning
3.1
Connecting Power
DANGER
Turn off main power before installing AC connections to the flowmeter. Contact with
exposed wiring may lead to fire, electric shock, or serious personal injury.
1. Using a 1/16" Hex key, loosen the flowmeter Rear Housing Cover locking setscrew.
2. Unscrew the Rear Housing Cover and remove.
3. Locate power supply connector J8. Use the tables below and the part number of your unit
to determine the correct input power source. (See ID label on right side of housing.)
①
②
③
④
Power Supply Option Code
S
ZN
ZP
Note
Power Supply Module P/N label is located inside the front housing cover.
4. Pull the desired length of input power wires through flowmeter case conduit cable hole
and into flow meter case before wiring connector.
SITRANS FUH1010 Quick Start
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
All manuals and user guides at all-guides.com
Flowmeter Number
Transducer Type
Relay Type
Numeric Display
Power Supply P/N
1010X-6SS2
1010X-6ZNS2
1010X-6ZPS2
⑤
Power Supply Option
⑥
Language Option
⑦
Safety Rating Option
User Supplied Power
90-250 VAC Single Phase
9-36 VDC Negative Ground
9-36 VDC Positive Ground
3
17