Commissioning
3.5 Transducer Installation
10. Take either transducer and apply a continuous lengthwise 1/8-inch bead of coupling
compound across the center of the transducer emitting surface.
①
②
③
Figure 3-6
11. Slide transducer into a Mounting Frames back end first aligning the angled edge of the
transducer with the angled edge of the Mounting Frame. Keep transducer from making
contact with the pipe until it butts up against the Mounting Frame stop.
12. Tighten the transducer Clamping Screw to hold the transducer in place.
installation procedure for the other transducer
30
All manuals and user guides at all-guides.com
Coupling Compound
Emitting Surface
Back End
Transducer
④
Transducer
⑤
Angled Edge
⑥
F-Connector
.
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
Repeat
SITRANS FUH1010 Quick Start