Carefully switch the tool on.
Q
Make sure that the nozzle always
points away from you and any
bystanders.
Make sure not to drop anything into
the nozzle.
Cooling down
The nozzle and accessory become very hot during use.
Let them cool down before attempting to move or store
the tool.
To reduce the cooling time, switch the tool on at
Q
the lowest air temperature setting and let it run for
a few minutes.
Switch the tool off and let it cool down for at least
Q
30 minutes. Always place it vertical and standing.
When the inside of heat gun gets too
hot, the indication on the LCD blinks.
In that case, set the slide switch to
position 1 to cool down the tool.
After cooling down fully, restart the
operation.
If the LCD still blinks after the restart,
contact your local Makita Service
Center.
MAINTENANCE AND CLEANING
Attention:
work on the equipment, pull the
power plug.
Maintenance
Your Power Tool has been designed to operate
Q
over a long period of time with a minimum of
maintenance. Continuous satisfactory opera-
tion depends upon proper tool care and regular
cleaning.
If the supply cord is damaged, it must be replaced
Q
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Lubrication
Your power tool requires no additional lubrication.
Q
Cleaning
To prevent overheating of the motor, keep the
Q
ventilation slots of the machine clean and free
from dust and dirt.
Regularly clean the machine housing with a soft
Q
cloth, preferably after each use. If the dirt does not
come off use a soft cloth moistened with soapy
water.
Never use solvents such as petrol,
alcohol, ammonia water, etc. These
solvents may damage the plastic
parts.
Before performing any
TECHNICAL DATA
Model No:
HG6531C
Voltage:
Current:
Setting:
I
Temperature:[°C]
50
[°F]
122
Setting:
I
Air flow: [L/M] 200-550 200-550
[CFM]
7-19
Overall length
Net weight
Default setting of the preset mode
No.
Application name
1
FREE SET 1
2
FREE SET 2
3
SCRINKING
4
FORMING
5
SOLDERING COPPER
6
DRYING PAINT
7
PAINT STRIPPING
8
WELDING FLOOR FOIL
9
WELDING PPEPDM
10
WELDING HDPE
11
WELDING PP
12
WELDING PVC-U
13
WELDING ABS
14
WELDING PC
MAKITA LIMITED WARRANTY
Please refer to the annexed warranty sheet for the
most current warranty terms applicable to this product.
If annexed warranty sheet is not available, refer to the
warranty details set forth at below website for your
respective country.
United States of America: www.makitatools.com
Canada: www.makita.ca
Other countries: www.makita.com
Subject to change without notice.
6 English
HG6530V
120V~
120V~
14A
14A
II
I
II
50-650
50
50-650
122-1202
122
122-1202 122-1202
II
I
II
500
280
7-19
18
10
257mm
257mm
0.71kg
0.72kg
Temperature
250°C
500°C
300°C
250°C
650°C
650°C
450°C
450°C
280°C
300°C
320°C
340°C
360°C
380°C
III
50-650
II
550
19
Air volume
5
5
3
4
3
5
5
3
3
3
3
3
3
3

Publicidad

loading

Este manual también es adecuado para:

Hg6530vHg6530vk