Descargar Imprimir esta página

Balluff BTL7-A -M -A8-SA211-S32/KA Serie Instrucciones Breves página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
BTL7-A/C/E/G_ _ _-M_ _ _ _-A(8)-SA211/311-S32/KA _ _ /FA _ _
Micropulse Transducer - rod Style
Electrical connection
Pin Cable color
-A_10
1
YE yellow
Not used 1)
2
GY gray
3
PK pink
10 to 0 V 10 to –10 V
4
RD red
5
GN green
0 to 10 V –10 to 10 V
8
WH white
BTL7-_1_ _-...
6
BU blue
7
BN brown
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect the transducer and controller using a shielded
cable.
Shielding: Copper filament braided, at least 85%
coverage.
Connector version: Shield is internally connected to
connector housing.
Cable version: On the transducer side, the cable
shielding is connected to the housing.
Ground the cable shielding on the controller side
(connect with the protective earth conductor).
Magnetic fields
The position measuring system is a magnetostrictive
system.
It is important to maintain adequate distance between the
transducer cylinder and strong, external magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Installation
NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
► The mounting surface of the transducer must make
full contact with the supporting surface.
► The bore must be perfectly sealed (O-ring/flat seal).
www.balluff.com
-G_10
-C_00
-C_70
0 to 20 mA 20 to 0 mA 4 to 20 mA 20 to 4 mA
0 V
Not used 1)
La (programming input)
Not used 1)
Lb (programming input)
GND 2)
20 to 28 V
-E_00
-E_70
Pin assignment of S32 (view of connector
pins of transducer), 8-pin M16 circular plug
1) Unassigned leads can be connected to
GND on the controller side but not to the
BTL7-_5_ _-...
shield.
GND 2)
2) Reference potential for supply voltage
10 to 30 V
and EMC-GND.
Only use the proper nut for the mounting thread. Firmly
tighten the transducer with a maximum torque of 100 Nm.
If installing horizontally with nominal lengths > 500 mm, we
recommend tightening the rod at the end (only possible
with Ø 10.2 mm) or supporting it.
If installed in a hydraulic cylinder, the magnet should not
make contact with the rod. Minimum bore diameter in the
support piston:
Tube diameter
10.2 mm
8 mm
Startup
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
regularly (especially after replacing the transducer or
after repair by the manufacturer). Recalibrate the
transducer, if necessary.
The calibration procedure is described in the
comprehensive user's guide.
Bore diameter
At least 13 mm
At least 11 mm
DANGEr
english
2

Publicidad

loading

Este manual también es adecuado para:

Btl7-c -m -a8-sa211-s32/ka serieBtl7-e -m -a8-sa211-s32/ka serieBtl7-g -m -a8-sa211-s32/ka serieBtl7-a -m -a8-sa211-s32/fa serieBtl7-c -m -a8-sa211-s32/fa serieBtl7-e -m -a8-sa211-s32/fa serie ... Mostrar todo