TABLE 2: How to convert gas Source
Burners
Flame
Regular burners
Full flame
Saving flame
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving flame
position.
Remove the knob, and adjust the flame with a tiny screwdriver (see fig. 7 below)
To check the adjusted flame: heat the burner at full open position for 10 minutes. Then
turn the knob into the saving setting. The flame should not extinguish nor move to the
nozzle. If it extinguish or moves to the nozzle, readjust the valves.
Converting the
Converting the
hob from LPG
hob from natural
to natural gas
gas to LPG
Replace the burner
Replace the burner
nozzle according
Nozzle according
to the guidelines in
to the guidelines in
Table 1.
Table 1.
Loosen the
Loosen the
adjustment spindle
adjustment spindle
(see figure below)
(see figure below)
and adjust the
and adjust the
flame.
flame.