Descargar Imprimir esta página

Metabo HPT CR 18DMA Manual De Instrucciones página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Safeguard
LED Light Display
Function
On 0.1 second/
Overburden
off 0.1 second
Protection
On 0.5 second/
Temperature
off 0.5 second
Protection
8. Remaining battery indicator
You can check the battery's remaining capacity by
pressing the remaining battery indicator switch to
light the indicator lamp. (Fig. 28, Table 7)
The indicator will shut off approximately 3 seconds
after the remaining battery indicator switch is
pressed.
It is best to use the remaining battery indicator as
a guide since there are slight diff erences such as
ambient temperature and the condition of the battery.
Also, the remaining battery indicator may vary from
those equipped to a tool or charger.
(Battery is sold separately)
State of lamp
Lights ;
The battery remaining power is
over 75%
Lights ;
The battery remaining power is
50%–75%.
Lights ;
The battery remaining power is
25%–50%.
Lights ;
The battery remaining power is
less than 25%
Blinks ;
The battery remaining power
is nearly empty. Recharge the
battery soonest possible
Blinks ;
Output suspended due to high
temperature. Remove the
battery from the tool and allow it
to fully cool down.
Blinks ;
Output suspended due to
failure or malfunction. The
problem may be the battery so
please contact your dealer.
18
Table 6
Corrective
Action
Remove the
cause of the
overburdening.
Allow the tool
and battery to
thoroughly cool.
Table 7
Battery Remaining Power
As the remaining battery indicator shows somewhat
diff erently depending on ambient temperature and
battery characteristics, read it as a reference.
Remaining battery
indicator lamp
Display panel
NOTE
Do not give a strong shock to the display panel or
break it. It may lead to a trouble.
OPERATIONAL CAUTIONS
Resting the unit after continuous work
(1) The power tool is equipped with a temperature
protection circuit to protect the motor.
Continuous work may cause the temperature of the
unit to rise, activating the temperature protection
circuit and automatically stopping operation.
If this happens, allow the power tool to cool before
resuming use.
(2) After use for continuous works, rest the unit for
15 minutes or so when replacing the battery. The
temperature of the motor, switch, etc., will rise if
the work is started again immediately after battery
replacement, eventually resulting in burnout.
Remaining battery
indicator switch
Fig. 28

Publicidad