INSTRUCTIONS FOR USE
Weekly timer
Press and hold the "M" key on the remote control for 2 seconds. This turns on the clock regulation and by pressing the '+'
key, the weekly timer function is accessed, with the display showing the description "PROGRAMM ON/OFF".
This function allows you to set a number of times the insert turns on and off per day (up to a maximum of three), each
day of the week.
As you confi rm the display with the key "M", one of the following options will appear:
NO PROG. (no programme set)
DAILY PROGRAM (single programme for every day of the week)
WEEKLY PROGRAM. (specifi c programme for each day individually)
Use the "+" and "–" keys to switch between programmes.
Use key "M" to confi rm the option "DAILY PROGRAM" to choose the number of programmes (turn on/off) to be carried out per
day.
Use the "DAILY PROGRAM" to set identical programme/s for every day of the week.
By then pressing the "+" key, the following can be seen:
- Prog. no.
- 1st prog. (one turn on and one turn off per day), 2nd prog. (identical), 3rd prog. (identical)
Use the "–" key to show in reverse order.
If the 1st programme is selected, the turn on time is shown.
The display shows: 1 "ON" at 10 Use the "+" and "–" key to change the hour. Confi rm with the "M" key.
The display shows: 1 "ON" at 30 Use the "+" and "–" key to change the minutes. Confi rm with the "M" key.
The same applies for the turn-off time to be set and for subsequent turning on and off.
Confi rm by pressing "M" and the wording "SAVE??" will appear on the display.y.
When confi rming "WEEKLY PROGRAM", you will need to choose the day to which the programming is to apply:
1 Mon ; 2 Tues; 3 Wed; 4 Thurs; 5 Fri; 6 Sa; 7 Sat
Once you have chosen the day, use the "+" and "–" key and confi rm with the "M" key, to programme in the same way as for the
"DAILY PROGRAM", choosing whether or not to enable a programme for each day of the week, and if so choosing number of
interventions and at what times.
Should you make an error during programming, you can leave the programme without saving. As you press a key,
, he di-
splay will show the word "no SAVE".
Changing pellet loading
Press the "M" button for two seconds from the radio control and scroll the display instructions with the "+" and "-" buttons. You
will come across the message "User menu" and when you confi rm, the message "ADJ-PELLET and ADJ-DRAUGHT" will appear.
If we set "Auto-adjust. ON", the system will automatically adjust pellet dropping. Alternatively, if we set "Auto-adjust. OFF," we
can manually correct pellet dropping, varying the range in terms of percentages (+/- 30 %).
By confi rming this function with the menu key, you can access the function to adjust pellet loading. By decreasing the
value set, pellet loading is decreased. By increasing the value set, pellet loading increases. This function is useful if
changing the pellet type for which the stove has been calibrated and loading therefore needs correcting.
Should this correction not suffi ce, contact the Edilkamin-authorised Dealer, to establish the new operating axis.
Notes on fl ame variability
Flame status may vary depending on the type of pellet used, in addition to normal solid fuel fl ame variability and regular combu-
stion chamber cleaning carried out automatically by the boiler.
(N.B.: which does NOT replace necessary cold suction by the user prior to ignition).
RESERVE WARNING
The stove is fi tted with an electronic function that detects the residual quantity of pellets in the tank.
The detection system is integrated into the electronic board, allowing you to see how many hours and kg are left until
pellet exhaustion, at all times. For correct system function, it is important that the following procedure is followed during the fi rst
ignition (by the Dealer).
- 33
-