EdilKamin NANCY Instalación Uso Y Mantenimiento página 38

Ocultar thumbs Ver también para NANCY:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
POSSIBLE TROUBLESHOOTING
7) Signalling:
smoke °C/high.
Problem:
turns off due to exceeding maximum smoke temperature.
Actions:
• Check the pellet type
• Check for anomalies with the smoke extraction motor
• Check to see if there are any obstructions in the smoke channel
• Check correct installation
• Check gear motor "drift"
• Check to make sure there is an air intake in the room
8) Signalling:
"Battery check"
Problem:
The insert does not stop but the error appears on the display.
Actions:
• The buffer battery of the control board needs changing (DEALER).
9) Problem:
Remote control not working
Actions:
• closer to the receiver of the insert
• check the battery and if necessary, replace it.
10) Problem:
Outlet air not hot
Actions:
• clean heat exchanger from inside the fi rebox.
11) Problem:
During ignition, the differential switch trips (DEALER):
Actions:
• check moisture content of ignition resistance
12) Problem:
Does not ignite:
Actions:
• clean combustion chamber.
NOTA 1
All signals/warnings remain shown until you intervene on the remote control, by pressing the button
Do not use the insert before having eliminated the problem.
NOTA 2
After 1000 kg of pellets consumed, the display fl ashes the wording 'Mainten.'.
The stove works, but you must call the Dealer out to perform extraordinary maintenance.
- 38
-
.

Publicidad

Tabla de contenido
loading

Tabla de contenido