2.4
Hygiene
2.4.1 Damage to health caused by dirty, polluted or
long standing water
Operating the shower functions with dirty, polluted or
long standing water can cause damage to health.
> Supply the product with cold drinking water from the
main water system.
> Do NOT connect any waste water, grey water,
industrial water, sea water or other untreated or semi-
treated water.
> Only use the water supply hoses provided with the
product. Do NOT reuse old hoses.
> If the product is NOT to be used for two weeks or more,
empty the product and switch it off (holiday mode).
2.5
Avoid product damage
2.5.1 General precautions
> Only use the parts in the installation kit to avoid
malfunctions.
> Only use attachments recommended by Duravit.
2.5.2 Damage through freezing water
> Do NOT install and operate the product in rooms where
there is a danger of frost. The room temperature must
not be less than 4 °C (39 °F).
2.5.3 Damage due to limescale build-up
Limescale can build-up in regions with hard water.
Limescale can impair the performance of the product.
> Check the water quality in the region. Duravit
recommends the installation of a water softener with
water hardness ≥ 14 °dH (2.5 mmol/l).
3
Requirements at the installation location
The pre-installation is carried out properly.
> Access the pre-installation data sheet at qr.duravit.com
or www.duravit.com.
> Ensure that there is enough floor space to install the
toilet and that bathroom door will open and close
without obstruction.
> Ensure that the lid will open and close without
obstruction against window frames, shelves and other
bathroom furniture.
MI
4
Drawings and plans
4.1
Water and power connections
180 mm
(7 ⅛ ")
IG ½ "
90 mm
(3 ½ ")
> Ensure that the water connection and drain are
installed in the specified areas.
> Ensure that the electrical connection is installed in the
specified areas.
5
Technical data
Electrical connection
Rated voltage
Rated power
Circuit breaker
RCD
Protection degree
Protection class
Cable specification
Water connection
Cold water
Water pressure
Water hardness
70000785
90 mm
(3 ½ ")
220 – 240 V, 50 – 60 Hz
1080 W
I
 = 16 A
N
I
 = 30 mA
N
IPX4
I
Supply line cross section
2
1 – 2.5 mm
(17 – 14 AWG)
DN 15 (½")
0.07 – 0.75 MPa
(10 – 109 psi)
Max. 2.4 mmol/l
(240 ppm)
57313
23.02.3
7