6
Mounting instructions
Inspecting the product
1
> Inspect the product for damages.
Preparing the water connection
2
The water connection can be prepared as follows:
– Via a permanent connection.
> Use an additional pre-installation set.
– Via ductwork in the cistern, often pre-assembled on
®
DuraSystem
carrier frames.
> Check if ductwork is pre-assembled.
> Use an additional connection set.
Installing a noise reduction gasket
4
> Take the thickness of the noise reduction gasket into
consideration during installation: z + 50 mm (2 ").
Connecting the water
8
NOTE
Malfunctions caused by defective hoses
> Only use the water supply hoses provided with the
product. Do NOT reuse old hoses.
Installing the connection set for toilet
10
> Observe the seperate manual.
Do not bend or kink hose
13
> Ensure that the hose is not bent or kinked.
Flushing the pipes
17
NOTE
Malfunctions caused by dirty pipes
> Open the main valve for the water supply.
> Open the stop valve.
> Flush the pipes according to the local standards and
collect the water.
> Close the stop valve for the water supply.
Checking for leaks
> Check for leaks.
Choosing and installing mounting clip
22
The delivery contains several mounting clips.
> Choose the mounting clip according to cable diameter.
MI
Connecting the wires
24
WARNING
Risk of fatal injury caused by electric shock
Contact with electricity can lead to a fatal electric shock.
> Read and observe the information given in the safety
chapter of this manual.
> Remove approximately 10 mm (⅜ ") of insulation from
the wires.
> Connect the three wires to the terminal block. Observe
the L, N and PE conductors.
> Ensure that the protective earthing conductor is
10 mm (⅜ ") longer than the L and N conductors.
 – 
Installing interface with electronic actuator
27
28
plate (optional)
Applies only to:
#650000 01 2 00 4320, #650001 01 2 00 4310.
#650002 01 2 00 4300 is connected via Bluetooth.
> Install the Interface Set for functional interface with
®
DuraSystem
actuator plate A2
> Observe the seperate manual.
Checking for leaks
33
> Check for leaks.
Installation options remote control:
– Option A: glued or screwed [} 84]
– Option B: glued or screwed [} 86]
 + 
 + 
Testing the product
A8
A17
B8
B17
> Check if the product works properly.
> Observe the user manual.
CAUTION
Damage to health caused by dirty, polluted or long
standing water
Operating the shower functions with dirty, polluted or
long standing water can cause damage to health.
> If the product is NOT to be used for two weeks or more,
empty the product and switch it off (holiday mode).
70000785
8
57313