MOUNTING AND CONNECTION TO POWER SUPPLY
Please refer to the illustrations in the Quick Start Guide.
1. IMPORTANT! (fig. 1) Always switch off the power supply before installation.
2. The spotlight is delivered with the bracket mounted. For easy installation, it is a good idea to dismantle the bracket of the
spotlight and use it as a template for the drilling distance of the holes (fig. 2).
3. Use the bracket to mark out the drill holes.
For versions with motion detector: The spotlight must be mounted at a height of less than 3 m (fig. 3). Recommended
mounting height for models with motion detector: 2.5 m.
4. Spotlights without motion detectors can be placed anywhere, but reduced brightness must be expected at a greater distance
from the illuminated area.
5. To fix the mounting plate to the wall, follow the steps as described in fig. 4 to 6.
6. Now attach the spotlight to the screwed-on bracket (fig. 7).
7. The swiss version is delivered with the cable connected. Points 8 to 12 can be skipped here.
8. To connect the spotlight, unscrew the cable lock (fig. 8).
9. Pay attention to the length specifications when stripping the cable.
The cable sheathing should be stripped a maximum of 20 mm, the wire insulation 12 to 14 mm (fig. 9). For safety reasons, the
PE line should always be longer than the L and N lines! This is enormously important for the tightness of the spotlight.
The length of the cable should be long enough to allow you to fix the spotlight in any position. In addition, you should make
sure that the cable is not routed towards the spotlight from above. We recommend a small bend so that rainwater does not
flow along the cable to the spotlight.
10. Slide the cable lock onto the cable (fig. 9).
11. Now connect the spotlight. To do this, insert the stripped strands into the respective marked sockets N, L and earth (fig. 10).
These are automatically tensioned by a spring, it is not necessary to screw them tight. You can release the stranded wire by
pressing the button.
12. Screw the middle part of the cable closure onto the spotlight and then the closing cap (fig. 11).
13. Adjust the spotlight to the desired beam angle and fix it in place (fig. 12).
14. Switch on the power supply again.
15. The motion detector can be adjusted horizontally by 75° and vertically by 70° to the front / 90° to the rear (fig. 16 and 17).
DESCRIPTION OF FUNCTION
(only for versions with motion detector/ PIR)
This spotlight is equipped with an infrared sensor. It switches on automatically as soon as the sensor detects movement in the
surroundings.
If possible, do not point the motion detector at swimming pools, heating vents, air conditioners or objects that are subject to
large temperature fluctuations.
Avoid pointing the motion detector at trees or bushes or at places where pets might often be present.
The motion detector can be turned horizontally to the right and left and tilted vertically up and down.
When mounting the spotlight, bear in mind that the motion detector is most sensitive to movements that pass across its field of
detection and least sensitive to movements that pass directly towards the unit.
Permanent function
The spotlight can be switched on in permanent mode for approx. 4 hours. After 4 hours, the spotlight automatically switches back
to normal mode with motion detector.
The permanent function can be activated by switching on three times within 5 seconds (On / Off / On / Off / On). By switching off/
on again, the spotlight is back in motion detector mode.