5. Pinout
Power Supply
12VDC
G
Note
3
1
Lens connection
Signal level
Remark
3
1
Lens connection
Signal level
24VAC
Only switch on the power supply when all the other connections have been
carried out. The use of power supply units with stabilised output voltage
(12VDC ±10%) is recommended.len.
DC voltage controlled lenses
1
4
2
3
2
4
E/I switch in off-position
A/I switch in dc-position
To be optimized with LEVEL potentiometer
Use only DC voltage controlled lenses with internationally standardized plug pinout.
Videosignal controlled lenses
1
4
2
3
2
4
E/I switch in off-position
A/I switch in video-position
To be optimized with ALC control setting at the lens.
G
Description
Damping (-)
Damping (+)
Control (+)
Control (-)
Description
Supply voltage (+)
N.C.
Video
Ground
20
Colour
red
-
white
black