The pipe size must be set to ensure the flow is calculated and displayed properly . To set the pipe size, navigate to the
Flow Options screen and press the ■ NEXT button until the pipe diameter value is highlighted . Press the
GREEN buttons to increase or decrease the value until the appropriate pipe size is selected . Press the ■ SET button
to set the pipe diameter and the =DONE button to exit the menu .
This completes the initial setup of the system . If there are no other desired configuration changes, the system is ready to
use . For additional configuration options, see the next section "CONFIGURING YOUR SYSTEM" .
7 CONFIGURING YOUR SYSTEM
MENU NAVIGATION
The Setup Menu provides access to all of the Navigator Pro's settings, options, and calibration procedures . The menu
options are as follows:
• Display
o Auto Dim
o LCD Brightness
o Numeric Position on Graph
• Presets
o Number of Presets
o Preset Positions
• Alarm limits
o Pressure Alarm Limit
o Flow Alarm Limit
• Diagnostics
• OEM Configuration
o Valve Setup
• Valve Assignment
• Valve Name
• Valve Name
• Valve Number
• Valve Color
• Valve Calibration
• Valve Options
• Motor Installed yes/no
• CAFS on/off
• Auto Open
o Valve Download
o Pressure Setup
• Calibration
• Pressure Options
• Display Units
• Zero Offset
• Use Factory Defaults
o Flow Setup
• Calibration
• Flow Options
• Display Units
• Zero Offset
• Pipe Size
• Use Factory Defaults
Page 11