8 OPERATIONAL FEATURES
The Style 9335 Navigator Pro Controller has been designed to be intuitive and easy to use . Once configured, the opera-
tion is simple . Basic operation of the controller is described below .
8.1 Opening and closing the valve
GREEN button . To close the valve, press the RED button . As
To open the valve using the Navigator Pro, press the
soon as either button is released, the valve will stop moving . To continue opening or closing the valve, continue to hold
the appropriate button . The only exception to this is if Auto Open is enabled (see "Valve Options" under Section 7 .6,
VALVE SETUP & CALIBRATION) .
GREEN button . The Auto Open
The Auto Open feature enables the user to fully open the valve with one press of the
feature is only available if the valve is fully closed . To stop an auto-open procedure in progress, press either the RED or
GREEN button again at any time . This will stop the valve and allow it to be adjusted to the desired position .
8.2 Preset operation
The Navigator Pro is capable of saving up to 3 valve positions . After the positions are saved (see Section 7 .2, PRESETS,
for details), a preset position can be selected to cause the valve to immediately move to that position . To send the valve
to a preset position, simply press the PRESET button . The first available saved preset will start blinking . If that is the
desired preset position, press the GOTO button and the valve will go to that position . If the second or third preset is
desired, press the NEXT button until the desired preset blinks, and then press the GOTO button to send the valve to
that position . The presets are labeled P1, P2 and P3 for normal operation . If CAFS is enabled, the presets are labeled D,
M and W, which stand for Dry, Medium and Wet, respectively . When the valve is at a preset position, the preset label will
be highlighted in green .
8.3 CAFS operation
The Navigator Pro has the capability to operate a solenoid valve to turn the compressed air to the CAFS system on and
off . If installed and configured as a CAFS controller, the blue button below the screen will be available to turn the CAFS
on and off during normal operation . To enable, see "Valve Options" under Section 7 .6, VALVE SETUP & CALIBRATION .
To turn the CAFS on, press the CAFS button once . The box above the CAFS label will display "ON?" and blink for 5
seconds . Press the CAFS button again within 5 seconds to confirm and turn CAFS on . If no action is taken within 5
seconds, it will time out and return to OFF . To turn the CAFS off, use the same procedure: press the CAFS button once
again so that "OFF?" is displayed and will blink for 5 seconds . Press the CAFS button again within 5 seconds to confirm
and turn CAFS off .
Note: To enable CAFS operation, the CAFS solenoid must be connected to pin 5 of the six-pin Display connector on the
valve (see Section 5 .1, "ELECTRICAL INSTALLATION") .
Page 21