6 Configuration
Name
(c)
In
Type of unit:
▪ 0: Secondary unit
▪ 1: Primary unit
Lht
Light state
(c)
nrt_1
Network temperature regulation for secondary unit 1:
▪ 0: The controller regulates through the probe connected to
itself,
▪ 1: The controller regulates through the probe connected to
the Primary unit.
(c)
nrt_2
Network temperature regulation for secondary unit 2:
▪ 0: The controller regulates through the probe connected to
itself,
▪ 1: The controller regulates through the probe connected to
the Primary unit.
(c)
nrt_3
Network temperature regulation for secondary unit 3:
▪ 0: The controller regulates through the probe connected to
itself,
▪ 1: The controller regulates through the probe connected to
the Primary unit.
(c)
nrt_4
Network temperature regulation for secondary unit 4:
▪ 0: The controller regulates through the probe connected to
itself,
▪ 1: The controller regulates through the probe connected to
the Primary unit.
(b)
On
ON/OFF command (button on user interface):
▪ 0: Off
▪ 1: On
PAL
Probes Alarm active
PDS
Service password
(b)
PDU
User password
PPu
Valve opening percentage
PPuB
Valve opening percentage 2
r4
Automatic night-time set point variation
r4d
Night temperature regulation differential
rd
Temperature control differential
rSA
Reset alarms
rH
Maximum monitored probe value (read only)
rHP
Reset HACCP event log
rL
Minimum monitored probe value (read only)
rM
Enable temperature monitoring
rSA
Reset alarms
rt
Monitoring session period (read only)
rtA
Current date
rtL
Monitoring period reset
rtm
/
SAK
Alarm history visualisation (read only)
Sc
Condenser temperature
ScB
Condenser temperature circuit 2
Sdt
Discharge temperature compressor 1
SdtB
Discharge temperature compressor 2
SH
Actual superheating reading circuit 1
SHB
Actual superheating reading circuit 2
Installation manual
22
Description
Default
Min.
Max.
1
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
22
0
999
0
0
999
0
0
100
0
0
100
3
-50
50
∆°C/°F
4
0,1
99.9
∆°C/°F
2/
0.1/
99.9/
∆°C/°F
3.6
0.2
179.2
0
0
1
0
0
0
0
0
1
0
0
0
0
0
1
0
0
1
0
0
0
dd/mm/
0
0
yyyy
0
0
1
dd/mm/
0
0
yyyy
E6
0
0
-17.1
0
55.4
0
0.6
0
(a)
UoM
Menu
App
%
%
CtL
°C/°F
PSd
°C/°F
ALM
h
dir
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728170-1B – 2023.07

Publicidad

loading

Este manual también es adecuado para:

Lmsey1a13avm01Lmsey2a19aye01Lmsey2a25aye01