Descargar Imprimir esta página

Daikin LMSEY1A09AVM01 Manual De Instalación página 27

Ocultar thumbs Ver también para LMSEY1A09AVM01:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 119
9
Disposal
Wooden, plastic and polystyrene packing must be disposed of
according to the regulations in force in the country where the unit is
used.
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation.
Final disposal of the unit must be done by an authorised
area technical assistance service, that has proper training,
equipment and instructions for the dismantling. They are
also responsible for reuse, recycling and recovery.
CAUTION
There are potential environmental hazards involved in
dismantling the unit.
10
Technical data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
10.1
Wiring diagram
▪ A printed version of the declaration of conformity, the wiring- and
piping diagrams is included with the unit.
Wiring diagram legend
For applied parts and numbering, refer to the wiring diagram on the
unit. Part numbering is by Arabic numbers in ascending order for
each part and is represented in the overview below by "*" in the part
code.
Symbol Meaning
Symbol Meaning
Circuit breaker
contact
MS
Compressor
3
Connection
Connector
Contactor contact
M
Expansion valve
MS
Fan
Fuse
M
Fuel pump
M
Generator
3
Heater
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728170-1B – 2023.07
Noise filter
Power supply plug
Pressure switch
p
Protective earth
Relay
Relay contact
Resistor
Solenoid valve
Speed sensor
Temperature sensor
Terminal
Symbol Meaning
Symbol Meaning
Inverter reactor
Main switch
LMSEY1A09+13AVM01
Symbol
Meaning
ACU
Unit controller
CF1
Condensor fan
C1
Compressor
C1 (cable)
Supply cable
C2 (cable)
Door heater cable
C3 (cable)
Room light cable
C4 (cable)
Door switch cable
C5 (cable)
Inverter supply cable
C6 (cable)
PWM inverter 1 cable
EDH
Evaporator drain heater
EF1
Evaporator fan
EVM
Electronic expansion valve
F1
Main line fuse
F2
Main neutral fuse
F3
Line aux fuse
F4
Neutral aux fuse
HMI
User interface
HMI cable
User interface cable connection
HPS
High pressure switch
INV
Inverter compressor
J21A
TH1-TH7 probes male connector
J21B
TH1-TH7 probes female connector
J22A
PWM inverter male connector
J22B
PWM inverter female connector
J23A
TH3-TH5-TH6 probes male connector
J23B
TH3-TH5-TH6 probes female connector
J24A
Room light + door switch male connector
J24B
Room light + door switch female connector
J29A
Supply inverter male connector
J29B
Supply inverter female connector
K1M
Drain heater relay
K2M
Drain heater relay
K3M
Compressor relay
RDH
Room door heater
RDS
Room door switch
RL
Room light
SV2
Defrost solenoid valve 1
TH1
Discharge compressor probe
TH3
Suction air probe
TH5
Evaporator inlet probe
TH6
Evaporator outlet probe
TH7
Condensor probe
X1M
Suppy cable terminal
X2M
Phase terminal
X3M
Neutral terminal
X4M
Output terminal
9 Disposal
Terminal strip
Transformer
Installation manual
27

Publicidad

loading

Este manual también es adecuado para:

Lmsey1a13avm01Lmsey2a19aye01Lmsey2a25aye01