EN
Introduction
Thank you for purchasing this Silverline tool. This manual contains information necessary
for safe and effective operation of this product. This product has unique features and, even if
you are familiar with similar products, it is necessary to read this manual carefully to ensure
you fully understand the instructions . Ensure all users of the tool read and fully understand
this manual .
Description of Symbols
The rating plate on your tool may show symbols. These represent important information about the
product or instructions on its use .
Wear hearing protection .
Wear eye protection .
Wear breathing protection .
Wear head protection .
Wear hand protection .
Read instruction manual .
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for recycling
advice .
Caution!
Toxic fumes or gases!
Class II construction (double insulated for additional protection)
Conforms to relevant legislation and safety standards .
4
264569_Manual.indd 4
264569_Manual.indd 4
Original Instructions
Specification
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V~ 50Hz
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200W
No load speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800 – 3500min
Spindle thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M14, male
Backing Pad diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180mm
Cable length: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 .0m
Ingress Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP20
Protection Class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions (L x W x H): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460 x 80 x 200mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.55kg
As part of our ongoing product development, specifications of
Silverline products may alter without notice.
Sound and vibration information:
Sound pressure L
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 .6dB(A)
PA
Sound power L
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 .6dB(A)
WA
Uncertainty K: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3dB
Weighted vibration a
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 .871m/s
h
Uncertainty K: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 .5m/s
The sound intensity level for the operator may exceed 85dB(A)
and sound protection measures are necessary .
WARNING: Always wear ear protection where the sound level exceeds 85dB(A) and limit the time
of exposure if necessary. If sound levels are uncomfortable, even with ear protection, stop using the
tool immediately and check the ear protection is correctly fitted and provides the correct level of
sound attenuation for the level of sound produced by your tool .
WARNING: User exposure to tool vibration can result in loss of sense of touch, numbness, tingling
and reduced ability to grip . Long-term exposure can lead to a chronic condition . If necessary, limit
the length of time exposed to vibration and use anti-vibration gloves. Do not operate the tool with
hands below a normal comfortable temperature, as vibration will have a greater effect. Use the
figures provided in the specification relating to vibration to calculate the duration and frequency
of operating the tool .
Sound and vibration levels in the specification are determined according to international standards.
The figures represent normal use for the tool in normal working conditions. A poorly maintained,
incorrectly assembled, or misused tool, may produce increased levels of noise and vibration .
www.osha.europa.eu provides information on sound and vibration levels in the workplace that
may be useful to domestic users who use tools for long periods of time.
General Power Tool Safety Warnings
WARNING: Read all safety warnings, instructions, illustrations and specifications
provided with this power tool. Failure to follow all instructions listed below may result in electric
shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-
operated (cordless) power tool.
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or
fumes.
c) Keep children and bystanders away while operating a power tool. Distractions can cause you
to lose control.
2) Electrical safety
a) Power tool plugs must match the outlet. Never modify the plug in any way. Do not use
any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching
outlets will reduce risk of electric shock.
b) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges
and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase
the risk of electric shock.
d) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power
tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled
cords increase the risk of electric shock.
e) When operating a power tool outdoors, use an extension cord suitable for outdoor use.
Use of a cord suitable for outdoor use reduces the risk of electric shock.
-1
2
2
05/08/2021 12:22
05/08/2021 12:22