All operating elements and connections can be
GB
found on the fold-out page 3.
1 Operating Elements
and Connections
1 Locking screw (2 ×) for the mounting bracket
2 Laser outlet
3 Mounting bracket
4 DMX signal output (3-pole XLR) for connection
to the DMX input of another DMX light effect
unit;
pin 1 = ground, 2 = DMX-, 3 = DMX+
5 Mains jack for connection to a socket (230 V~ /
50 Hz) via the supplied mains cable
6 Support for the mains fuse
Only replace a blown fuse by one of the same
type
7 Key switch for the laser protection adviser: the
laser beam cannot be switched on with the key
removed
8 DIP switches
switches 1 to 9 for the DMX operation to adjust
the DMX start address
switch 10 for independent operation to adjust
master unit or slave unit
9 Control for the response sensitivity in case of
music control via the microphone (10)
10 Microphone for music control
11 DMX signal input (3-pole XLR) for connection of
a light controller;
pin 1 = ground, 2 = DMX-, 3 = DMX+
8
2 Safety Notes
The unit corresponds to all required directives of
the EU and is therefore marked with
2.1 Special notes for lasers
The laser has the following power and wavelength
and corresponds to the following laser class:
Model
Power
LSX-049SG
4.9 mW
LSX-40SG
40 mW
LSX-80SR
80 mW
WARNING 1. The unit must be installed so that
nobody will be able to look directly
into the laser beam. Already a short
radiation on the retina may cause
permanent damage. Unintentional
reflections must be prevented.
2. The laser area must be limited and marked dur-
ing operation.
3. A laser protection adviser must be appointed in
writing and be present during operation (regu-
lation BGV B2 of the German employerʼs liabil-
ity insurance).
4. In addition for units of class 3b
models LSX-40SG and LSX-80SR
The operation of the laser must be notified at
the employerʼs liability insurance association
and the trade board.
2.2 General safety notes
WARNING The unit is supplied with hazardous
mains voltage. Never make any
modification on the unit and do not
insert anything through the air vents!
This may cause an electric shock
hazard.
It is essential to observe the following items:
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient tempera-
ture range 0 – 40 °C).
G
Do not place any vessels filled with liquid, e. g. a
drinking glass, on the unit.
G
Do not set the unit into operation, and immedi-
ately disconnect the mains plug from the mains
socket if
1. there is visible damage to the unit or to the
mains cable,
.
Laser
Wavelength
Class
532 nm (green) 3r
532 nm (green) 3b
650 nm (red)
3b