Maintenance
The Belle Group 'PCLX' range is designed to give many years of trouble free operation. It is recommended that an approved Belle
Group dealer carries out all major maintenance and repairs. Always use genuine Belle Group replacement parts, the use of spurious
parts may void your warranty.
Before any maintenance is carried out on the machine, switch off the engine and disconnect the HT lead from the sparkplug.
Always set the 'PCLX' on level ground to ensure any fl uid levels will be correctly read. Only use recommended oils (see chart on follow-
ing page).
Running In Period
When the 'PCLX' is fi rst used from new, the engine oil must be changed after the initial running in period (see engine manual for full de-
tail). The vibrator shaft case oil must be replaced after the fi rst 100 hours use, then after every 500 working hours. For detail on vibrator
shaft case oil replacement, see 'Vibrator unit'.
The belt tension should be checked after 4 hours use.
Routine Maintenance
Engine Oil
Air Filter
Spark Plug
Drive Belt
Oil / Fuel Type & Quantity - Spark Plug Type
Petrol Honda GX100
Vibrator
Service & Maintenance
Check Level
Change
Check Condition
Clean / Replace
Check / Clean
Tension
Oil type
Quantity
(Litre)
S.A.E. 10W 30
Turbine Oil 32
Vibrator Unit.
Remove the plug complete with seal, check that the oil level reaches the bottom thread on the oil
plug hole. Top up as necessary with the correct oil (see chart).
After First
4 hours
Fuel Type
0.4
Unleaded
0.22
N/A
13
First month / 3 Months
20Hours
50 Hours
Capacity
Spark Plug
(Litre)
Type
1.2
BM4a or
BmR4a
N/A
N/A
GB
6 months
100 Hours
Electrode
Gap (mm)
0.6 - 0.7
N/A