EN- ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be entrusted
only to an electrician perfectly to the fact of the normative regulations and which respects them
scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers place on the hob casing near the connection
box.
• The connection to the main must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for example: circuit
breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated in
the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or oven.
Caution!
This appliance must only be connected to a network 230 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the 1
st
bridge between terminal L1 and L2, the 2
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L to one of
the terminals L1 or L2.
Biphase
400V~2P+N
Put a bridge between terminal 4 and 5.
Attach the earth to the terminal "earth", the neutral N to terminal N1 or N2, the Phase L1 to the
terminals L1 and the Phase L2 to the terminal L2.
Frequent loosening and screwing of the screws on the connection box risks damaging the
efficiency of the tightness once screwed. It is therefore advisable to keep screwing and
unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
4 weeks after installation, be sure to tighten again the screws in the terminal block.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
nd
between N1 and N2.
32
Protection calibre
25 A *
16 A *

Publicidad