SECURITY DISTANCES
From NOT combustible object :
•
A > 400 mm B > 100 mm C > 100 mm D > 1000 mm
−
From combustible object and from principal wall in rein forced concrete :
•
A > 800 mm B > 200 mm C > 200 mm D > 1000 mm
−
The minimal distance between the stove and every object around it is 1 mt
•
1.4 Connection
Before connection check the technical data reported in the technical plate and control
•
that they correspond to the ones required in the order (See duplicatet Chap. 4).
All heating biomass equipments especially wood and pellet stove have to evacuate the
•
combustion products in a flue, built in conformity with the normative in force.
The following instructions describe „ informations for a good installation „ and refer to a
•
normative in force but they are not to be consider exhaustive for installations laws.