Descargar Imprimir esta página

Lincar Monellina 176PL PLUS Manual Del Usuario página 49

Publicidad

Idiomas disponibles

Idiomas disponibles

ORDINARY COMBUSTION ROOM CLEANING
The combustion room is to clean periodic to keep a good functioning. We recommend
one a month but it depends on operating day time of stove, quality pellet etc. This
operation is to do by qualify staff
Combustion Room Cleaning (fig. 5 – 6):
Before starting the cleaning , please would You check if You have the spare part for
the seal;
Take away : head and tank cover (fig. 5);
Unscrew the two nuts and take away the head protection, Unscrew the last four nuts
and take away the cap of closing room (fig. 6);
To clean with the appropriate brush the space between tubes of heat exchange also
with a vacuum cleaner;
Replace everything with attention to the seal gasket position (to substitute if
necessary) and the sheet must be replaced with the fold on top as showed in the dart.
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - ES
ES mod. 156P PLUS - 176PL PLUS 2018
GB
GB
FR
FR
ES
ES
Fig. 5
Fig. 6
A
A
49/108
Combustion
Cleaning (fig. 7):
Unscrew the dowel M.5
"A" who fixed the fire
door.
Take away the fire door
with attention to ceramic
parts.
Unscrew the four dowels
and take away the cap.
Clean with a vacuum
cleaner.
Replace everything with
attention to ceramic parts
Room

Publicidad

loading

Este manual también es adecuado para:

Birikkina 156p plus