1-1 ACCESSORIES
Name
Pleated filter
Quantity
1 pc.
Shape/
Number
Relay harness
Name
(Small)
Quantity
1 pc.
Shape/
Number
CAUTION
• When installing, also refer to the installation manuals of the indoor unit, the remote controller, and the
decoration panel.
Pay special attention to the items below during installation and check them again
after completion.
(1) Items to be checked after completion of work
Test item
Are the indoor unit, UV streamer air purifier unit and
decoration panel securely installed?
(Be sure all screws have been tightened and there
are no unsealed gaps.)
Did you check the indoor unit after completing its
installation?
Did you make local settings by using the remote
controller?
Is the air inlet free from obstructions?
Is pleated filter (1) installed?
Is the protective net installed?
Did you seal the indoor unit using the supplied
sealing material (8)?
During trial operation, did you confirm that the indicator on
the Corner cover with operation display (5) turns blue?
Has the wiring been done correctly, without sagging
wires?
Refer to the following table for models to which the UV streamer air purifier unit can be mounted.
3
01_EN_3P701968-3.indd 3
01_EN_3P701968-3.indd 3
Clamp
8 pcs.
(2)
(1)
Wire clamp
1 pc.
(6)
(7)
Relay harness
Glass tube
(Large)
(Large)
1 pc.
1 pc.
(3)
(4)
Sealing material
1 pc.
(8)
• Installation manual
• Operation manual
Resulting problems
Falling, condensation, vibration
Operation malfunction, burning, danger in
case of short circuit
Capacity decline, condensation
Purification performance degradation
Capacity decline
Inability to emit UV
Abnormal noise
Operation malfunction
Operation malfunction, burnout
Corner cover with
operation display
1 pc.
(5)
Other
Check
column
English
12/05/2023 15:12:24
12/05/2023 15:12:24