INSTALLING YOUR FURNACE
WARNING: Remove 4" x 14" fiberglass gasket
from bottom of header plate and discard. This gasket is
not used when the furnace is recessed in the wall.
FIGURE 10
GAS SUPPLY OPENING
A hole must be drilled for the gas line supply.
Decide whether the gas line will come through the floor or
wall stud.
NOTE
If a pre-existing gas piping stub location is not compatible
with hole or knock-out provided in furnace, you may make
an alternate entry hole in the furnace back wall as shown
on Figure 14.
CAUTION: Be careful not to damage any furnace
components while making any alternate hole.
Locate and drill one (1) 1-1/2 inch hole at selected locations
as shown on Figure 11, Figure 13 or Figure 14.
Gas line can be run at this time or done after furnace is
mounted, see section GAS SUPPLY AND PIPING, page 18.
12
COUNTERFLOW TOP VENT GAS WALL HEATER
FIGURE 11
CLOSE OFF STUD SPACE (IF REQUIRED)
If studs are not on 16 inch centers, cut the hole for the
furnace next to an existing stud and frame in the other
side using a 2 x 4 and spacer blocks as required. As
shown on Figure 12.
ELECTRICAL SUPPLY ROUGH-IN
Run the electrical supply with the ground wire and
thermostat cable into stud space next to furnace location.
FIGURE 12 - CLOSED OFF STUD SPACE (IF REQUIRED)
CAUTION: Do not run wire behind flanges of header
plate or in any location where it might be damaged.
Avoid splicing thermostat wire unless the spliced wires
are properly cleaned, soldered and taped.