INTRODUCTION
Basic Tools Needed
Hand drill or properly grounded electric drill
Expansion bit 1/2" to 1-5/8" or 1/2" and 1-1/2" blade bits
1/8" and 3/16" drill bit (metal)
6 ft. folding rule or tape measure
Screwdriver (medium blade)
Screwdriver (Phillips and Flat Head)
Pliers (wire cutting)
Hammer
Stud Locater or small finishing nails
Tin Snips
8" adjustable wrench
12" adjustable wrench
7/8" wrench
3/4" wrench
1" wrench
Gloves and safety glasses
Materials
Pipe and fittings to make connections to furnace See
page 19.
Caulking compound(silicone rubber with a temperature
rating of 500°F.
DO NOT use caulking compound advertised as paintable or
for bath tub use as most contain fillers and will not withstand
high temperatures.
Pipe Joint Compound resistant to propane gases.
Electrical wiring supplied as needed see page 27. Minimum
wire size is #14 gauge copper.
Trim Accessory 4701 is recommended or 3/4" Quarter Round
or other wood trim molding approximately 16'long.
Oval Vent Kit 9901 is recommended.
Vent Enclosure Kit 9812 or 9824 if furnace is to be surface
mounted is recommended.
1 x 1 wood strips if Optional Side Outlet Grille Register
6701 is used.
Helpful Installation Information
The following booklets will help you in making the installation:
ANSI/NFPA 70 (1990 or current edition "National Electrical Code".
In Canada: CSA C22.1 Canadian Electrical Code. American
National Standard NFPAS4/ANSI Z223.1 1988 or current
edition "National Fuel Gas Code".
Obtained from: American National Standards Institute, Inc.,
1430 Broadway, New York, N Y 10018.
In Canada: CAN/CGA B149.
6
COUNTERFLOW TOP VENT GAS WALL HEATER
Optional Accessories
DIFFUSER GRILLE KITS 6703 & 6704
6703 let's you route some heated air in a two-way direction.
Kit 6704 for one-way direction.
SIDE OUTLET GRILLE KIT 6702
Allows you to direct heated air from the side of furnace into
the same room.
OUTLET GRILLE REGISTER 6701
Let's you route some heated air into a second room. Mounts
on the side wall of second room and must be within 10 inches
of wall furnace.
REAR OUTLET KITS 6801 & 6802
Let's you route some heated air into a second room behind
the furnace. Finished wall of second room must be within
10 inches of furnace as shown on Page 8, Figure D. Built(in
damper lets you shut off air flow to second room if desired.
OVAL VENT KIT 9929
This U.L. listed B/W vent kit contains 4 feet of oval double
walled vent pipe, plate spacers and starter or hold-down plate
that starts the venting from the top of the furnace. See page
15 for additional items you will need.
VENT ENCLOSURE KITS 9812 or 9824
These kits are used only when the furnace is surface
mounted. They enclose the vent pipe from the top of the
surface to the ceiling.
TRIM STRIP KIT 4701
Provides finished edge at sides of wall furnace. Neutral beige
enamel painted steel.
THERMOSTAT 78355
Unpacking Your Furnace
The furnace is shipped in one carton containing the furnace,
installation instruction booklet and hardware bag.
1. Lay carton horizontally. Open carton and remove top
trim cover from its packing. Remove thumb screw at top
of furnace, raise top front panel ½ inch and remove
panel from cabinet. This is so you can get to the electrical
connections later.
2. Place these and other parts, as they are removed from
furnace, where they cannot be lost or damaged before you
need them.
3. Bottom front panel can be removed by grasping just below
handle and pulling it outward and then upward.
See Figure 1.
NOTE
Check the burner rating plate, located in burner
compartment, to make sure your furnace is equipped
to operate on the type of gas available (either natural or
propane gas).
4. Remove all literature, wire and metal anchors used for
free standing installation.
5. Check the fan blade to be sure it spins freely.