HOW TO KEEP YOUR COZY FURNACE OPERATING
6.
Wait five (5) minutes to clear out any gas, then smell
for gas, including near the floor. If you then smell gas,
stop! Follow "B" In the safety information above. If
you don't smell gas, go to the next step.
7.
Loosen wing nut and open pilot observation door
(If equipped).
8.
To find the pilot, follow the metal tube from gas
control. The pilot is mounted on the side of the burner.
9.
Turn knob on gas control counterclockwise
to PILOT
10. Push in the red reset button all the way and hold in.
Immediately light the pilot. Continue to hold the
red reset button in for about (1) minute after the pilot
is lit. Release button and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 10.
•
If button does not pop up when released, stop and
immediately call your service technician or
gas supplier.
•
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11.
Close the pilot observation door and tighten wing nut
(if equipped).
12. Turn gas control knob counterclockwise
to "ON". The knob can be turned to "ON" only if red
reset button is up.
13. Replace the control access panel.
14. Turn on all electric power to the appliance.
15. Set thermostat to the desired setting.
To turn OFF gas to appliance
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if service is
to be performed (if applicable).
3.
Remove the control access panel.
4.
Push in the gas control knob slightly and turn it
clockwise to "OFF". Do not Force.
5.
Replace the control access panel.
IMPORTANT: KEEP BURNER AND CONTROL
COMPARTMENT CLEAN.
WARNING: DUE TO HIGH SURFACE
TEMPERATURES, KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE
MATERIAL AWAY FROM FURNACE.
24
COUNTERFLOW TOP VENT GAS WALL HEATER
How To Care For Your Furnace
WARNING: Danger of bodily injury or death.
Turn off electric power supply at the disconnect
switch, fuse box or service panel before removing any
doors or access or service panels from the unit.
CABINET FINISH
Clean the cabinet with damp rag. Never use abrasive
cleaners. Cabinets are finished in heat resistant powder
coated finish DO NOT refinish with wall paint.
COMBUSTION AND VENTILATION AIR
The combustion and ventilation air supply must not
be blocked.
Do not put anything in or on the furnace cabinet.
For better circulation and more effective heating, do not
place obstructive furniture closer than four feet to the
front of the cabinet or two feet to either side of the cabinet.
FURNACE AREA
Keep the area near the furnace clear and free from
combustible materials, gasoline, and other flammable
liquids and vapors.
ANNUAL UPKEEP NEEDED
It is recommended that a qualified service technician
perform these checks at the beginning of each
heating season.
CLEANING AND OILING
Shut off electricity, and then remove cabinet door and
front panel. Clean any lint or dirt from fan blades, fan
motor, and exposed air passages. Use a brush.
Put 5 drops of SAE 20 oil in each of the two cups or oil
tubes on the fan motor, See Figure 36, below.
FIGURE 36 - MOTOR OIL HOLES
PILOT BURNER
Light pilot using instructions in OPERATING YOUR
FURNACE (on pages 22 and 23, depending on your
model). Leave thermostat at lowest setting.
Pilot flame should surround 3/8 to 1/2 inch of the
thermocouple tip. Refer to Figure 28, Page 25. If flame
needs adjusting, do it as follows: