FIGURE 17 - CEILING PLATE SPACERS
FIGURE 18
INSTALL SURFACE VENT (SURFACE MOUNT)
NOTE
For surface mounting, it will be helpful to complete the gas
piping supply to the furnace before installing the vent pipe.
See section GAS SUPPLY & PIPING, page 17.
Carefully move the furnace into position under the ceiling
cutout.
Insert first lengths of oval, double wall vent pipe up through
the ceiling cutout. Lower vent pipe to the hold-down plate.
Push the vent pipe into the hold-down plate until it is
completely seated. (Hold-down cleats will engage the groove
in the vent pipe.)
FIGURE 18 – ALTERNATIVE VENTING
IF VENT EXTENDS OVER 5 FEET
ABOVE ROOF, GUY OR BRACE.
SEAL AROUND COLLAR
AND FLASHING
SUPPORT IF
NECESSARY
MAINTAIN
LISTED
CLEARANCE
MAXIMUM VERTICAL RISE
TYPE B ROUND OR OVAL
MINIMUM
HEIGHT
12 FEET
COUNTERFLOW TOP VENT GAS WALL HEATER
MAINTAIN LISTED
CLEARANCE
LOCK JOINTS
SUPPORT LATERALS
FIRE STOP
INSULATION SHIELD,
IF ATTIC IS INSULATED
MULTISTORY
UPPER FLOORS
ATTACH
HEADER
SHEET
PLATE
METAL
SLEEVE
CEILING
SPACER
HEATER HEADER
PLATE
SINGLE STORY
OR FIRST FLOOR
OF MULTISTORY
SPACE
SEAL AND
BASE PLATE
15