hoses, fixed piping etc. are connected to the pump on the pressure
side. This ensures that the pump can be completely filled with water (2 l)
(air can escape).
The pump is to be filled with 2 l of water.
3.3.2 Silent operation:
The pump is silent. This advantage can only be maintained with the
correct installation:
v Choose a low-vibration base (e. g. do not place on metal sheets or
plastic tanks).
3.3.3 Max. flow values:
The pump has a bypass valve to enable short suction times. If the hose
end is open and there are no devices connected, or if the hose diameter
is very large, the valve may not be able to switch from suction to pumping
mode due to the hydraulic pressure conditions. This may cause increased
operating noise. In order to enable the full pumping capacity, close the
water outlet for approx. 1 second while the engine is running (e. g. by kin-
king the hose). This allows the valve to assume its correct position, which
is audible as one click. In standard applications with connection devices
such as showers or sprinklers, this happens automatically.
3.3.4 Assembly of prefilter:
If a prefilter is too long, it can be assembled in another position
(e. g. horizontally) instead of vertically downwards.
4. MAINTENANCE
DANGER!
Risk of injury!
Risk of injury due to accidental starting.
v Unplug the plug of the mains cable from the mains socket.
4.1 To clean the pump:
DANGER!
Risk of injury!
Risk of injury and risk of damage to the product.
v Do not clean the product with water or with a water jet
(in particular high-pressure water jet).
v Do not clean with chemicals including petrol or solvents.
Some can destroy critical plastic parts.
v Clean the pump housing with a damp cloth.
4.2 To flush the pump:
After pumping chlorinated water, the pump must be flushed.
1. Pump through lukewarm water (max. 35 °C), possibly adding a mild
cleaning agent (e. g. detergent) until the pumped water runs clear.
2. Dispose of the residues in accordance with local waste disposal
regulations.
5. STORAGE
5.1 To put into storage [ Fig. S1 ]:
CAUTION!
Damage to the pump due to frost!
v Store the pump in a frost-free place.
The product must be stored away from children.
1. Unplug the plug of the mains cable from the mains socket.
2. Close any shut-off valves in the suction line.
3. Open any shut-off valves in the pressure line (accessories, water
stop, etc.).
Therefore the pressure line is depressurised.
12
9057-20.960.03.indd 12
9057-20.960.03.indd 12
(5)
4. Unscrew the screw connection
drain screw
(8)
by hand.
Therefore the pump is drained.
5. Tilt the pump in the direction of the drain (approx. 80°) so that the
pump empties completely.
6. Unscrew the suction hose and the pressure hose.
7. Tighten the screw connection
(5)
drain screw
(8)
by hand (do not use pliers).
8. Clean the pump (see 4. MAINTENANCE).
9. Store the pump in a dry, enclosed and frost-free place.
6. TROUBLESHOOTING
DANGER!
Risk of injury!
Risk of injury due to accidental starting.
v Unplug the plug of the mains cable from the mains socket.
6.1 To loosen the impeller [ Fig. T1 / T2 ]:
An impeller blocked by dirt can be loosened.
1. Only for Art. 9058 / 9059:
of the soil moisture sensor or unplug the
Pull off the dirt cover
(d)
connected soil moisture sensor.
ß
ß
2. Unscrew the 6 screws
,
and
9a
9b
(10)
3. Pull off the two shells
.
4. Remove the rubber plug
(11)
from the shaft of the impeller
5. Turn the shaft of the impeller
(12)
clockwise with an insulated screw driver.
Therefore the blocked impeller is loosened.
6. Reassemble the rubber plug
(11)
and the two shells
Make sure that you match the screws
screw holes depending on the length.
7. Only for Art. 9058 / 9059:
Reinsert the dirt cover
(d)
of the soil moisture sensor or reinsert the
soil moisture sensor.
6.2 To clean the filter [ Fig. T3 ]:
If the pump does not start or stops suddenly during operation, this may
be due to a clogged filter.
1. Close all existing shut-off valves on the suction side.
2. Open any shut-off valves in the pressure line (connection devices,
water stop, etc.).
This depressurises the pressure side.
3. Unscrew the screw fitting
(5)
of the filler neck
4. Pull the filter
(13)
vertically out of the filler neck
(14)
5. Hold the cup
firmly and turn the filter
the cup
(14)
(bayonet lock).
6. Clean the cup
(14)
under running water.
7. Clean the filter
(13)
e.g. with a soft brush.
(13)
8. Reassemble the filter
in reverse order.
6.3 Only for Art. 9058 / 9059:
To clean the non-return valve [ Fig. T1 / T4 ]:
1. Only for Art. 9058 / 9059:
of the soil moisture sensor or unplug the
Pull off the dirt cover
(d)
connected soil moisture sensor.
ß
ß
2. Unscrew the 6 screws
,
and
9a
9b
(10)
3. Pull off the two shells
.
4. Unscrew the cap
(15)
counterclockwise with an Allen key (width 10).
5. Pull the flow sensor
(16)
out of the sensor opening
6. Clean the flow sensor
(16)
under running water.
7. Clean the sensor opening
ß
with a damp cloth (without detergent).
z
8. Check the mobility of the flow sensor
(16)
9. Reassemble the flow sensor
(10)
10. Reassemble the two shells
in reverse order.
11. Only for Art. 9058 / 9059:
(d)
Reinsert the dirt cover
of the soil moisture sensor or reinsert the
soil moisture sensor.
(6)
of the filler neck
and the water
on the filling opening
(6)
and the water
ß
.
9c
(12)
.
(10)
in reverse order.
ß
,
ß
and
ß
to the correct
9a
9b
9c
(6)
by hand.
(6)
.
(13)
counterclockwise out of
ß
(see 6.1 To loosen the impeller).
9c
ß
.
z
(16)
.
in reverse order.
28.04.23 12:40