TECHNICAL DATA
BATTERY CHARGER
Voltage range .........................................................................................................
Quick charge current ..............................................................................................
Weight according EPTA-Procedure 01/2014 ..........................................................
Recommended ambient charging temperature ......................................................
WARNING! Read all safety warnings and all instructions. Failure to
follow the warnings and instructions may result in electric shock, fi re and/or
serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Do not dispose of used battery packs in the household refuse or by burning
them. Milwaukee Distributors off er to retrieve old batteries to protect our
environment.
Only the following battery packs can be charged with this charger:
Battery Cat. No.
Cell Type
DC Volts
Capacity
M12B
Li-Ion
12 V
≤ 1.5 Ah
M12BX
Li-Ion
12 V
≤ 3.0 Ah
M12B2
Li-Ion
12 V
≤ 2.0 Ah
M12B3
Li-Ion
12 V
≤ 3.0 Ah
M12B4
Li-Ion
12 V
≤ 4.0 Ah
M12B6
Li-Ion
12 V
≤ 6.0 Ah
M14B
Li-Ion
14.4 V
≤ 1.5 Ah
M14BX
Li-Ion
14.4 V
≤ 3.0 Ah
M14B4
Li-Ion
14.4 V
≤ 4.0 Ah
M18B
Li-Ion
18 V
≤ 1.5 Ah
M18BX
Li-Ion
18 V
≤ 3.0 Ah
M18B2
Li-Ion
18 V
≤ 2.0 Ah
M18B4
Li-Ion
18 V
≤ 4.0 Ah
M18B5
Li-Ion
18 V
≤ 5.0 Ah
M18B6
Li-Ion
18 V
≤ 6.0 Ah
M18B9
Li-Ion
18 V
≤ 9.0 Ah
M18HB3
Li-Ion
18 V
≤ 3.0 Ah
M18HB4
Li-Ion
18 V
≤ 4.0 Ah
M18HB5.5
Li-Ion
18 V
≤ 5.5 Ah
M18HB8
Li-Ion
18 V
≤ 8.0 Ah
M18HB12
Li-Ion
18 V
≤ 12.0 Ah
Do not try to charge non-rechargeable
batteries with this charger.
Do not store the battery pack together with metal objects (short circuit risk).
No metal parts must be allowed to enter the battery section of the charger (short
circuit risk).
Never break open battery packs or chargers and store only in dry rooms. Keep
dry at all times.
The battery clamps of the charger are fed by the mains supply. Do not touch the
tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or material fatigue.
Repairs should only be carried out by authorised Service Agents.
This appliance is not intended to be used or
cleaned by persons with reduced physical,
sensory or mental capabilities, or lack of
experience or knowledge, unless they have
been given instructions concerning the safe
use of the appliance by a person legally
responsible for their safety. They should be
supervised whilst using the appliance. Children
shall not use, clean or play with this appliance,
8
ENGLISH
M12-18 FC
...........12 V, 14,4 V, 18 V
..................................6 A
..............................703 g
............................ +5...+40 °C
which when not in use should be secured out
of their reach.
Warning! To reduce the risk of fi re, personal injury, and product damage due to
a short circuit, never immerse your tool, battery pack or charger in fl uid or allow
a fl uid to fl ow inside them. Corrosive or conductive fl uids, such as seawater,
certain industrial chemicals, and bleach or bleach containing products, etc., can
cause a short circuit.
SPECIFIED CONDITIONS OF USE
This charger charges 12V, 14.4V and18V Milwaukee Li-Ion battery packs.
Cell No.
Do not use this product in any other way as stated for normal use.
3
2 x 3
MAINS CONNECTION
3
Connect only to single-phase AC current and only to the system voltage
3
indicated on the rating plate. It is also possible to connect to sockets without an
2 x 3
earthing contact as the design conforms to safety class II.
2 x 3
CHARGING TIME
4
2 x 4
Battery Cat. No.
Volts
Capacity
2 x 4
M12B
12 V
≤ 1.5 Ah
5
M12B2
12 V
≤ 2.0 Ah
2 x 5
M12B3
12 V
≤ 3.0 Ah
5
M12BX
12 V
≤ 3.0 Ah
2 x 5
M12B4
12 V
≤ 4.0 Ah
2 x 5
M12B6
12 V
≤ 6.0 Ah
2 x 5
M14B
14.4 V
≤ 1.5 Ah
3 x 5
M14BX
14.4 V
≤ 3.0 Ah
5
M14B4
14.4 V
≤ 4.0 Ah
5
M18B
18 V
≤ 1.5 Ah
2 x 5
M18B2
18 V
≤ 2.0 Ah
2 x 5
M18BX
18 V
≤ 3.0 Ah
3 x 5
M18B4
18 V
≤ 4.0 Ah
M18B5
18 V
≤ 5.0 Ah
M18B6
18 V
≤ 6.0 Ah
M18B9
18 V
≤ 9.0 Ah
M18HB3
18 V
≤ 3.0 Ah
M18HB4
18 V
≤ 4.0 Ah
M18HB5.5
18 V
≤ 5.5 Ah
M18HB8
18 V
≤ 8.0 Ah
M18HB12
18 V
≤ 12.0 Ah
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the battery
indicates the state of charge.
If it is not used for long periods, the rechargeable battery will switch to the
non-operative state.
When fully discharged the rechargeable battery switches off automatically (depth
discharge not possible).
Under extreme circumstances, the internal temperature of the battery could
become to high. If this happens, the battery will shut down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the rechargeable
battery. The battery can be left in the electric tool while the reading is taken but it
must be switched off at least one minute beforehand (otherwise the display will
be inaccurate). The number of LEDs illuminated indicates the state of charge. A
fl ashing LED indicates a max. power reserve of 10%.
As a general principle, if the electric tool should fail to work after inserting the
rechargeable battery, then the battery should be plugged into the charger. The
displays on the battery and charger will then provide information about the
condition of the battery.
In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger the battery will
automatically be charged (red control lamp is illuminated continuously)
When a hot or cold battery pack is inserted into the charger (fl ashing red lamp),
charging will begin automatically once the battery reaches the correct charging
temperature (0°C...65°C). The max. charging current is fl owing when the
temperature of the Li-Ion-battery is between 0°C and 65°C.
The battery's charging time is between 1 min and 20 min (at 1,5 Ah), depending
on the state of discharge.
Once the battery is fully charged, the LED on the charger changes from red to
green.
Remove the battery pack from the tool for charging when convenient for you and
your job. Milwaukee batteries do not develop a memory when charged after only
a partial discharge. It is not necessary to run down the battery pack before
placing it on the charger.
As a general practice, it is best to unplug battery chargers and remove batteries
when not in use. No battery pack damage will occur, however, if the charger
and battery pack are left plugged in.
If both LEDs fl ash alternately then the rechargeable battery is either not fully
pushed in or there is a fault with the battery or charger. Take the charger and
battery out of use immediately for safety reasons and have them inspected by a
Milwaukee customer service centre.
Both 12V and 14.4/18V battery packs can be inserted into the charger at the
same time, but they will be charged one after the other. The fi rst battery pack to
be inserted will be the fi rst one to be charged. The red LED for the second
battery pack will fl ash slowly to indicate that the charging process has not begun
yet.
Charging Time
LIGHT INDICATORS
approx.
20 min
20 min
Continuous red
50 min
52 min
52 min
95 min
Slow fl ashing green
20 min
52 min
52 min
20 min
Continuous green
20 min
52 min
52 min
59 min
Fast fl ashing red
90 min
90 min
36 min
Slow fl ashing red
45 min
67 min
81 min
130 min
Flashing red/green
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods Legislation
requirements.
Transportation of those batteries has to be done in accordance with local,
national and international provisions and regulations.
• The user can transport the batteries by road without further requirements.
• Commercial transport of Lithium-Ion batteries by third parties is subject to
Dangerous Goods regulations. Transport preparation and transport are
exclusively to be carried out by appropriately trained persons and the process
has to be accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and insulated to prevent
short circuit.
• Ensure that battery pack is secured against movement within packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
If the supply cord of this appliance is
damaged, it must only be replaced by a repair
shop appointed by the manufacturer, because
special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described, please contact
one of our Milwaukee service agents (see our list of guarantee/service
addresses).
If needed, an exploded view of the tool can be ordered. Please state the Article
No. as well as the machine type printed on the label and order the drawing at
your local service agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before starting the machine.
Do not burn used battery packs.
Never charge a damaged battery pack.
Replace with a new one.
Charging
Do not dispose electric tools, batteries/rechargeable batteries
together with household waste material.
Electric tools and batteries that have reached the end of their life
Approaching full charge
must be collected separately and returned to an environmentally
compatible recycling facility.
Check with your local authority or retailer for recycling advice and
collection point.
This tool is only suitable for indoor use. Never expose tool to rain.
Charging is complete
Battery is too hot/cold - Charging will
begin when battery reaches correct
Time-lag fuse 5 A
T5.0A
charging temperature
Double isolated
Battery charge is pending - Charging
will begin when the fi rst pack is fully
charged
European Conformity Mark
Damaged or faulty battery pack
British Confomity Mark
Ukraine Conformity Mark
EurAsian Conformity Mark
ENGLISH
9

Publicidad

loading

Este manual también es adecuado para:

4932451079