Menu item
Description
Set detection time
Determines the minimum
[Detection time]
detection time within the detection
range to be recognised as a user.
Activate preflush
When the user is detected, a flush
[Preflush]
is actuated for 3 seconds if there
has been no use in the last
10 minutes.
Activate attendance flush
Flushing takes place as long as
[Attendance
there is a user in the detection
flush]
range (maximum 60 seconds).
Note: This function results in a
higher level of water consumption.
Activate postflush
An additional flush of 2 seconds is
[Postflush]
actuated 3 seconds after a main
flush.
Check detection range
Indicates when the sensor detects
a user. The sensor can be recal-
ibrated in the event of detection
faults or a change in environment.
The environment is re-evaluated in
the process.
[Detection range]
Set [detection range]
[Recalibrate sensor]
Note: There must be no objects in
front of the IR sensor during calib-
ration.
Volumetric flow rate
To calculate the water
[Volumetric flow
consumption for the statistics
rate]
function, the volumetric flow rate
of the urinal flush control must be
specified.
Presettings
[Save as
The current settings are saved in
presetting]
the app, which means they can be
transferred to other devices.
Factory settings
[Factory settings]
All functions are reset to factory
settings.
90071995661314699 © 11-2022
970.650.00.0(01)
Application
• To prevent flushes due
to unintentional entry
into the detection range
• To wet the urinal
ceramic before use to
avoid deposits
• To ensure thorough
flushing out of the
urinal ceramic
• As background noise
• To fill the urinal trap
• To test user recognition Automatic
• To optimise user recog-
nition
• In the event of
detection malfunctions
• In the event of a
changed environment
• To commission several
devices with the same
settings
• To remedy
malfunctions
Area
Factory
setting
3–15 s
7 s
On/Off
Off
On/Off
Off
On/Off
Off
Short to long
Long
distance
distance [4]
[0–4]
[Start calib-
ration]
9 l/min
14 l/min
18 l/min
14 l/min
5–50 l/min
(user-
defined)
3 / 3