PROBLEM
Engine will not start.
Engine hard to start.
Engine lacks power.
AC receptacle does not work.
If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance.
NOTICE:
As the equipment owner, you are responsible for the performance of the required maintenance listed in the Maintenance
section. It is recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing
to perform the required maintenance may increase emissions, decrease fuel efficiency, degrade performance, cause
irreversible engine damage and/or void your warranty.
TROUBLESHOOTING
POSSIBLE CAUSE
Easy Start dial is in OFF/STORAGE or
RUN/RE-START position.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Spark plug faulty, fouled, or improperly
gapped.
Engine stored without treating or
draining gasoline, or refueled with bad
gasoline.
Dirty fuel filter.
CO sensor LED is flashing red, indicat-
ing a CO hazard.
CO sensor LED is flashing yellow and/
or making an audible chirp, indicating
a sensor fault.
Water in gasoline.
Weak spark at spark plug.
Engine stored without treating or
draining gasoline, or refueled with bad
gasoline.
Dirty air filter.
Item plugged in is defective.
Generator is overloaded.
19 — English
SOLUTION
Move Easy Start dial to COLD START
position.
Fill fuel tank.
Drain entire system and refill with fresh
fuel.
Engine is equipped with Low Oil Shutoff.
If engine lubricant level is low, it must be
filled before unit will start. Check engine
lubricant level and fill, if necessary.
Replace spark plug.
Drain fuel and carburetor. Refuel with
fresh gasoline.
Contact a qualified service center.
Leave area immediately and relocate
to an open outdoor area. Ventilate area
thoroughly before occupying again.
Ensure the generator is located in an
open, outdoor area at least 20 feet away
from all doors, windows, and occupied
spaces, and point exhaust away from
occupied structures.
The CO sensor needs to be repaired or
replaced. Contact customer service or
a qualified service center for assistance.
Drain entire system and refill with fresh
fuel.
Replace spark plug or contact a
qualified service center.
Drain fuel and carburetor. Refuel with
fresh gasoline. If problem continues,
contact a qualified service center.
Clean or replace as needed.
Try a different item.
Remove loads and press the reset
button.

Publicidad